Switching waveforms – Cypress Perform CY7C136A User Manual
Page 10
CY7C132, CY7C136
CY7C136A, CY7C142, CY7C146
Document #: 38-06031 Rev. *E
Page 10 of 15
Figure 10. Busy Timing Diagram No. 2 (Address Arbitration)
Figure 11. Busy Timing Diagram No. 3 (Write with BUSY, Slave: CY7C142/CY7C146)
Switching Waveforms
(continued)
Left Address Valid First:
ADDRESS MATCH
t
PS
ADDRESS
L
BUSY
R
ADDRESS MISMATCH
t
RC
or t
WC
t
BLA
t
BHA
ADDRESS
R
ADDRESS MATCH
ADDRESS MISMATCH
t
PS
ADDRESS
L
BUSY
L
t
RC
or t
WC
t
BLA
t
BHA
ADDRESS
R
Right Address Valid First:
t
PWE
t
WB
t
WH
BUSY
R/W
CE