beautypg.com

Programming (cont.) – Culligan Sulfur-Cleer User Manual

Page 13

background image

9

If any of the days were set to “yes”, the display will show

“SETDAY” followed by “SUN”. This selects the current day of the

week. The “+” or “-“ key toggles through the days of the week

and pressing the “STATUS” key saves the setting and advances to

the next programming step.

If ALL of the days were set to “no”, then “days 03” will appear

as shown above and the regeneration interval will be set in

number of days. Pressing the “STATUS” key saves the setting and

advances to the next programming step.

• Cycle 1 Time (Backwash) -

This setting is used to program

the cycle 1 time that is usually backwash. The time of the cycle is

kept in minutes. The display will show “bw” in the left most digits

and the cycle time in the right most digits. Adjust the value with

the “+” or “-“ keys. Use the default value of 10 minutes, or the

appropriate time to allow the drain flow to be clear.

Pressing the “Status” key will save the setting and move to the next programming step.

• Cycle 2 Time (Brine Draw/Slow Rinse) - This setting is

used to set the time in minutes for cycle 2. This cycle is usually

brine draw / slow rinse for softeners and a settling time for filters.

The display will show “br” in the left most digits and the cycle time

in the right most digits. Adjust the value with the “+” or “-“ keys.

Adjust this cycle to 90 minutes if educting diluted bleach. Adjust

this cycle to 2 minutes if not educting diluted bleach.

Pressing the “Status” key will save the setting and move to the next programming step.

• Cycle 3 Time (Fast Rinse/Refill) - This setting is used to set

the time in minutes for cycle 3. This cycle is usually fast rinse for

softeners and filters. The display will show “Fr” followed by the

cycle time for this step. Adjust the value with the “+” or “-“ keys.

Adjust the cycle time to 6 minutes.

Pressing the “Status” key will save the setting and move to the

next programming step.

Programming

(cont.)

NOTE:
1. If any day of the week is set to “yes”, the regeneration interval in number of days (“Days

03”) will no longer appear when going through the programming menu at a later time.

To go back from specific day of week regeneration to interval in number of days, choose

“NO” at “dAYoWK”.

2. If a DIPswitch is changed anytime after the control has been programmed to regenerate

on any specific day, all settings will revert back to default; specific days to regenerate and

current day will have to be reprogrammed.

REGEN

REGEN