beautypg.com

En: installation sheet, Introduction, Installation guidelines – Interlogix VE1120 User Manual

Page 3: Installing the detector, J3 j4

background image

P/N 146279999-2 (ML) • REV C • ISS 28JUN12

3 / 32

7

VE1120

VE1120AM

VE1120

VE1120AM

Z

one X

1

2

3

4

5

6

7

GN

D

+12V

Alarm

Alarm Tamper

WT

Ta

m

p

er

J3

J4

8

D/N

CP

Z

o

ne Y

+12V

Ta

m

pe

r

WT

Ta

m

p

er

1

2

3

4 5

6

7

8

9

10

GN

D

Al

ar

m

D/

N

AM AM

Al

a

rm

Zone X

J3

J4

11

Rt

e

st

CP

Z

o

ne Y

+12

V

Ta

m

pe

r

WT

Ta

m

pe

r

1

2

3

4

5

6

7

8

9

10

GN

D

Ala

rm

D/N AM AM

Al

a

rm

Z

o

ne X

J3

J4

Z

one Y

+1

2V

Ta

m

per

WT

Ta

m

pe

r

GND

Al

arm

D/

N

AM AM

Ala

rm

Zone X

+

12V

Ta

mper

WT

Ta

m

p

er

GN

D

Al

arm

D/

N

AM AM

Al

ar

m

J3

J4

J3

J4

J3

J4

11

Rt

es

t

1

2

3

4

5

6

7

8

9

10

11

1

2

3

4

5

6

7

8

9

10

11

1

2

3

4

5

6

7

8

9

10

11

Rt

es

t

Rt

es

t

CP

CP

Z

one X

1

2

3

4

5

6

7

GND +1

2V

Al

a

rm

Al

a

rm

Ta

mper

WT

Ta

m

p

er

J3

J4

Zone X

GN

D

+1

2V

Alarm

Alarm Ta

m

pe

r

WT

Ta

m

p

er

GN

D

+12

V

Ala

rm

Ala

rm

Ta

mper

WT

Ta

m

pe

r

GND +12

V

Al

a

rm

Al

a

rm

Ta

m

p

er

WT

Ta

m

pe

r

J3

J3

J4

J3

J4

8

D/N

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

D/

N

D/

N

D/

N

J4

CP

(1)

(2)

Normal

larm

A
Tamper
Short

4.7 k
9.4

0

kΩ

8

Normal

larm

A
Tamper
Short

4.7 k
9.4

0

kΩ

8

+1

2V

Ta

m

pe

r

WT

Ta

m

p

er

GN

D

Ala

rm

D/N

AM AM

Al

ar

m

Rt

es

t

Normal

larm

A
Tamper
Short
AM/TF

4.7 k
9.4

0

kΩ

8

8

Normal

larm

A
Tamper
Short
AM/TF

4.7 k
9.4

0

kΩ

8

8

Normal

larm

A

< 33 Ω

8

Normal

larm

A

< 33 Ω

8

EN: Installation Sheet

Introduction

The VE1120 series includes the VE1120 PIR and VE1120AM
PIR-AM motion sensors. They have a patented mirror, pyro,
and signal processing technology.

Note:

VE1120AM has not been evaluated by UL/cUL.

Installation guidelines

The technology used in these detectors resists false alarm
hazards. However, avoid potential causes of instability (see
Figure 1) such as:

Direct sunlight on the detector

Strong draughts onto the detector

Heat sources within the detector field of view

Animals within the detector field of view

Obscuring the detector field of view with large objects,
such as furniture

Objects within 50 cm (20 in.) of the anti-masking (AM)
detector

Installing two detectors facing each other and less than
50 cm (20 in.) apart (only AM detectors)

Installing the detector

Figure 7 legend

Item Description

(1)

Standard connection (factory default)

(2)

Dual loop connection

CP Control

panel

WT Walk

test

AM Antimasking

D/N Day/night

Rtest Remote

test

To install the detector:

1. Lift off the custom insert and remove the screw

(see Figure 2, step 1).

2. Using a screwdriver, carefully prise open the detector (see

Figure 2, steps 2 and 3).

3. Fix the base to the wall between 1.8 and 3.0 m (5.9 and

9.8 ft.) from the floor. For flat mounting use a minimum of