Interlogix AP450 User Manual
Ap450 motion sensors installation instructions, Description, Parts
![background image](/manuals/679374/1/background.png)
AP450 Motion Sensors Installation Instructions
Description
The AP450 sensors (models AP450 and AP450A) are passive
infrared motion detectors that are highly sensitive to moving
infrared sources. They feature superior immunity to RFI,
vibration, static electricity, temperature changes, and other
false alarm sources.
The sensors provide jumper-selectable sensitivity, range, and
LED settings. The masks included allow the coverage pattern
to be modified for a wide variety of applications.
Figure 1: Exploded view
Base
Cover plate
Cover
Housing screw
LED
Parts
The following parts are included:
•
AP450 or AP450A sensor
•
Three factory-installed jumpers
•
Two plastic masks
•
Sheet of adhesive masking labels
•
Cardboard undercrawl window mask
•
One screw to secure the housing cover
Selecting a mounting location
Install the unit so that the expected movement of an intruder
will be across the detection pattern. See Figure 2 below.
Avoid possible false alarm sources such as:
•
Direct sunlight on the sensor
•
Heat sources in the field of view (heaters, radiators, etc.)
•
Strong air drafts onto the sensor (fans, air conditioning
etc.)
•
Large animals (dogs, cats) in a field of view The unit
should be mounted at a height of 6 to 10 feet (1.8 to
3.0m).
Caution:
You must be free of static electricity before handling
sensor circuit boards. Touch a grounded, bare metal surface
before touching circuit boards or wear a grounding strap.
Figure 2: Detection pattern
10.0 ft.(3.0m) maximum
8.0 ft.(2.4m) typical
6.0 ft. (1.8m) minimum
8 ft. (2.4m)
25 ft. (7.6m)
50 ft. (15.2m)
50 ft. (15.2m)
Mounting the sensor
1. To remove the cover plate, insert a flat-bladed screwdriver
between the notch on the top of the cover plate and the
cover. Pry up the cover plate. See Figure 1 above.
2. Remove the housing screw that holds the cover to the
base, insert a flat-bladed screwdriver into the slot above
the screw hole. Pry the cover off the base. See Figure 1
above.
P/N 1038277 • REV C • 17MAY11
1
Document Outline
- Description
- Parts
- Selecting a mounting location
- Mounting the sensor
- Selecting the coverage pattern
- Setting the sensitivity, range, and LED
- Pet alley application
- Operation information
- Maintaining the sensor
- Specifications
- Regulatory information
- Ordering information
- Contact information