APPENDIX B: COAXIAL CABLE LOSS REFERENCES

B.1 RG-6/U

B.1.1 Physical Characteristics (Overall)

B.1.1.1 Conductor Gauge:

#Coax AWG

Stranding

Conductor Material

Dia. (in.)

1 18 Solid BC-Bare

Copper

.040

B.1.1.2 Insulation Material:

Insulation Material

Dia. (in.)

GA-injected FPE-Foam Polyethylene

.180

B.1.1.3 Outer Shield Material:

Type

Outer Shield Material

Coverage (%)

Braid BC-Bare

Copper

95.0

B.1.1.4 Outer Jacket Material: PVC-Polyvinyl Chloride

B.1.1.5 Overall Cable:

Overall Nominal Diameter: 0.266 in.

B.1.2 Electrical Characteristics (Overall)

Nominal Characteristic Impedance: 75 ohm

Nom. Inductance: .097 µH/ft.

Nom. Capacitance Conductor to Shield: 16.3 µF/ft.

Nominal velocity of Propagation: 83%.

Nominal Delay: 1.21 ns/ft.

Nominal Conductor DC Resistance (DCR) at 20°C: 6.4 Ω/1000ft.

Nominal Outer Shield Conductor DC resistance (DCR) @ 20°C: 2.7 Ω/1000ft

Nominal Attenuation: