If the command entered is not recognized as a valid command, it will be ignored and
AccuTab II will send a “?” (question mark). If the delimiter following an invalid command
was an
Command Mode, awaiting a valid command.
A command may be aborted before entering a delimiter by sending a CTRL-X (hex 18). The
AccuTab II then ignores the preceding one or two characters and responds with a new
prompt.
To Leave Command Mode:
Send an
response to the Super L III’s prompt. AccuTab II returns to digitizing, now operating
according to the commands sent to it.
A Hint for Programmers
Here is the most efficient method for sending commands:
1. Send the CTRL-A and wait until the Controller responds with the prompt >. A loop
that retrieves one byte at a time from the serial port and checks for the > is best.
2. Send the command one character at a time. The Controller will respond by echoing
each character. Waiting for the character to be echoed will ensure that the
Controller has received the character and is waiting for the next one.
3. Once the command is complete, send a
mode.
4. If you send a
received. Then continue sending commands as described in step 2.
Advanced Programming Information
NOTE: The following information is not required for normal AccuTab II operation.
If you are programming for the AccuTab II product line, the topics listed below will be
useful:
Coordinate Formats
Measurement Scales