beautypg.com

How to order – EVCO EC6145 User Manual

Page 2

background image

Power supply:

230 Vac or 115 Vac or 24 Vac or 12-24 Vac/dc or

12 Vac/dc, 50/60 Hz, 5 VA.

Insulation class:

II.

Measure inputs:

2 (cabinet and evaporator probe) for PTC/NTC probes.

Digital inputs:

1 door switch (5 V, 1 mA) configurable to interact on the

outputs activity and for NO or NC contact.

Display:

green LED diode Ø 3 mm (0.11 in.) instrument status indi-

cator.

Outputs:

four NO contact relays of which one 16 (3) A @ 250 Vac

relay for one 1½ HP @ 250 Vac compressor management

and three 8 (3) @ 250 Vac relays for evaporator fans, de-

frost system management and for cabinet light control.

HOW TO ORDER

CODING SYSTEM
Instrument name:

EC 6-145.

Desired measure input:

P (for PTC/NTC probes).

Desired power supply:

220 (230 Vac)

115 (115 Vac)

A24 (24 Vac)

024 (12-24 Vac/dc)

012 (12 Vac/dc).

2

3