Options of mounting, Electro-mechanical characteristics, Electrical connections – EVCO EC3173 User Manual
Page 5: Size and piercing template

5
June '96
OPTIONS OF MOUNTING
With screw-brackets (A);
With spring-bracket (B).
The panel thickness will be between 1
and 5 mm.
ELECTRO-MECHANICAL CHARACTERISTICS
Box:
self-extinguishing plastic (PC-ABS)
according to UL94 V-0.
Size:
74 x 32 x 65 mm.
Mounting:
panel-mounting through fixing brackets.
Environment
temperature:
from 0 to +60 °C.
Humidity:
10 ... 90% not condensing.
Connections:
screw connectors.
Power-supply:
12 Vac/dc (standard) or 12-24 Vac/dc
(on request); 1,5 W.
Insulation-class:
II (with transformer, according to EN 60742).
Inputs for measure:
1 configurable for "J" or "K" thermocouples.
Range of measure:
from -99 to +700 °C ("J" thermocouple);
from -99 to +999 °C ("K" thermocouple).
Resolution:
1 °C.
Range of thermoregulator
programming:
from 0 to +999 °C.
Display:
3 digits display; output-status indicator.
Alarm buzzer:
included.
ELECTRICAL CONNECTIONS
Example of typical application.
SIZE AND PIERCING TEMPLATE
Measure in mm.
EVERY CONTROL S.r.l. - Via Mezzaterra 6 - 32036 Sedico - BELLUNO - ITALY
Phone 39 437/852468 (3 a.r. lines) - Fax 39 437/83648
Output:
one SPDT 8 A/250 Vac relay (output K1).
Serial port for data
exchange: