EVCO EVK214N9 User Manual
Page 4
Evco S.p.A. • Code 104K214E04 • page 4/6
10
OPERATIONAL SETPOINT AND CONFIGURATION PARAMETERSE
10.1 Operational setpoint
MIN.
MAX. U.O.M.
DEF.
r1
r2
°C/°F (1) 0,0
10.2 Configuration paramaters
PARAM. MIN.
MAX. U.O.M.
DEF.
SP
r1
r2
°C/°F (1) 0,0
PARAM. MIN.
MAX. U.O.M.
DEF.
CA1
-25,0 25,0
°C/°F (1) 0,0
CA2
-25,0 25,0
°C/°F (1) 0,0
CA3
-25,0 25,0
°C/°F (1) 0,0
P0
0
1
- - - -
1
P1
0
1
- - - -
1
P2
0
1
- - - -
0
P3
0
2
- - - -
1
P4
0
3
- - - -
3
P5
0
4
- - - -
0
P6
0
4
- - - -
0
PARAM. MIN.
MAX. U.O.M.
DEF.
r0
0,1
15,0
°C/°F (1) 2,0
r1
-99,0 r2
°C/°F (1) -50,0
r2
r1
99,0
°C/°F (1) 50,0
r3
0
1
- - - -
0
r4
0,0
99,0
°C/°F (1) 0,0
PARAM. MIN.
MAX. U.O.M.
DEF.
C0
0
240
min
0
C1
0
240
min
5
C2
0
240
min
3
C3
0
240
s
0
C4
0
240
min
10
C5
0
240
min
10
C6
0,0
200,0 °C/°F (1) 80,0
C7
0,0
200,0 °C/°F (1) 90,0
C8
0
15
min
1
C9
0
120
s
5
C10
0
9999 h
1000
PARAM. MIN.
MAX. U.O.M.
DEF.
d0
0
99
h
8
d1
0
1
- - - -
0
d2
-99,0 99,0
°C/°F (1) 2,0
d3
0
99
min
30
d4
0
1
- - - -
0
d5
0
99
min
0
d6
0
1
- - - -
1
d7
0
15
min
2
d8
0
3
- - - -
0
d9
-99,0 99,0
°C/°F (1) 0,0
dA
0
99
min
0
PARAM. MIN.
MAX. U.O.M.
DEF.
A0
0
2
- - - -
0
A1
-99,0 99,0
°C/°F (1) -10,0
OPERATIONAL SETPOINT
operational setpoint
OPERATIONAL SETPOINT
operational setpoint
INGRESSI DI MISURA
cabinet probe offset
evaporator probe offset
auxiliary probe offset (only if P4 = 1 or 2)
probe type
0 = PTC
1 = NTC
degree Celsius decimal point (for the quantity displayed during normal operation)
1 = YES
unit of temperature measurement (2)
0 = °C
1 = °F
evaporator probe function
0 = no probe
1 = defrosting probe and evaporator fan thermostat probe
2 = evaporator fan thermostat probe
fourth input function
0 = no probe
1 = sensor input (auxiliary probe, display probe)
2 = sensor input (auxiliary probe, condenser probe)
3 = digital input (multifunction input)
quantity displayed during normal operation
0 = cabinet temperature
1 = operational setpoint
2 = evaporator temperature
3 = "cabinet temperature - evaporator temperature"
4 = temperature detected by the auxiliary probe (only if P4 = 1 or 2)
quantity displayed by the remote indicator
0 = cabinet temperature
1 = operational setpoint
2 = evaporator temperature
3 = "cabinet temperature - evaporator temperature"
4 = temperature detected by the auxiliary probe (only if P4 = 1 or 2)
MAIN CONTROLLER
operational setpoint differential
minimum operational setpoint
maximum operational setpoint
block operational setpoint change (with the procedure indicated in paragraph 3.2)
1 = YES
temperature increase during Energy Saving function (only if P4 = 3 and i5 = 2 or 3); refer also to HE1 and HE2
COMPRESSOR PROTECTIONS (3)
compressor delay from device power on (4)
minimum time between two successive compressor operations; also compressor delay on resolution of cabinet probe error (5) (6)
minimum compressor shut-down time (5)
minimum compressor start-up time
duration of compressor shut-down during cabinet probe error; see also C5
duration of compressor start-up during cabinet probe error; see also C4
condenser temperature above which the condenser overheating alarm is activated (only if P4 = 2) (7)
condenser temperature above which the compressor block alarm is activated (only if P4 = 2)
compressor block alarm delay (only if P4 = 2) (8)
compressor 2 delay from power up of compressor 1 (only if u1 = 3)
number of hours of compressor operation above which maintenance request is indicated
0 = no function
DEFROSTING
defrost interval (only if d8 = 0, 1 or 2) (9)
0 = regular periodic defrosting will never be activated
type of defrosting
0 = electric
1= hot gas
defrost end temperature (only if P3 = 1)
defrost duration if P3 = 0 or 2; maximum defrost duration if P3 = 1
0 = defrosting will never be activated
defrosting at device power on (only if d8 = 1, 2 or 3) (4)
1 = YES
defrost delay from device power on (only if d4 = 1); see also i5 (4)
temperature displayed during defrosting (only if P5 = 0)
0 = cabinet temperature
1 = if, on activation of defrosting the cabinet temperature is below the "operational setpoint + r0", at most "operational setpoint + r0"; if on activation of defrosting the cabinet
temperature is above the "operational setpoint + r0", at most the cabinet temperature at activation of defrosting (10)
drip-drain duration
method of activation of defrosting
0 = PERIODIC - defrosting will be activated when the device has been left running for the length of time d0
1 = PERIODIC - defrosting will be activated when the compressor has been running for the length of time d0
2 = PERIODIC - defrosting will be activated when the evaporator temperature remains below the temperature set by d9 for the amount of time et by d0 (11)
3 = REAL TIME - defrosting will be activated at the times established by parameters Hd1 ... Hd6
the evaporator temperature above which the defrost interval count is suspended (only if d8 = 2)
minimum compressor on duration on activation of defrosting so that they may be activated (only if d1 = 1) (12)
TEMPERATURE ALARMS
temperature associated with the minimum temperature alarm
0 = cabinet temperature
1 = evaporator temperature (13)
2 = temperature detected by the auxiliary probe (only if P4 = 1 or 2) (14)
the temperature below which the minimum temperature alarm is activated; see also A0 and A2 (7)