STEP 2.
Remove hold-down screw and
terminal block cover.
Hold-down screw
Terminal block cover
STEP 3.
Attach a %-inch, U.L.-listed,
strain relief to the hole below terminal
block opening. Strain relief should have
a tight fit with laundry center cabinet and
be in a horizontal position. Put the direct
wire cable through the strain relief.
STEEP 4.
Loosen or remove terminal block
screws. Connect the neutral wire (white
or center) of direct wire cable under the
center screw of the terminal block.
STEP 4a.
Place the hook-shaped end
of the wire over the terminal block screw.
The open side of the hook should face
to the right. Squeeze hook end of wire
together to form a loop.
JÜUL
STEP 5.
Connect the other two wires to
outer terminal block screws using the
same method(s) described in STEP 4a.
Securely tighten all electrical connections.
STEP 6.
Tighten the strain relief screws.
STEP 7.
Insert tab of terminal block
cover into slot of the laundry center
rear panel. Secure cover with hold
down screw.
If local codes do not permit the
connection of a frame-grounding
conductor to the neutral wire, see
the instructions on page 21.
Otherwise, proceed with installation
on page 27.
Neutral grounding
wire (green/yellow)
Center silver-colored
terminal block screw
External ground
connector
Neutral wire
(white)
V4-inch, U.L.-listed,
strain relief
3-Wire Connection with Direct Wire
and Frame-Grounding Conductor
20