RECESSED AREA/CLOSET

INSTALLATION INSTRUCTIONS

Check governing codes and ordinances.

This laundry center may be installed in
a recessed area or closet.

The laundry center must not be installed
where it can be exposed to water and/or
weather.

• Proper operation of washer cycles

requires temperatures above

32°F

(at lower temperatures, some water
may remain in washer). See page 58

for Winterizing Information.

• Proper operation of dryer cycles

requires temperatures above 45°F- (at
lower temperatures, the dryer may not

shut off at the end of automatic cycles
and drying times will be extended).

• Check code requirements. Some

codes limit or do not permit installation
of laundry centers in garages, closets,
mobile homes, or sleeping quarters.
Contact your local building inspector.

WARNING: To reduce the risk of fire, this
appliance must be exhausted outdoors.

NOTE: No fuel burning appliances
may be installed in the same closet

as the laundry center.

MINIMUM INSTALLATION SPACING

*

1

"

FRONT VIEW

(DOOR NOT SHOWN)

SIDE VIEW

(DOOR SHOWN)

FRONT VIEW

(DOOR WITH VENT)

• Addilional clearances for wall, door and lloor moldings may be required.

** Opening is minimum lor closet door. Louvered door wilh equivalent air openings

is acceptable.

** * Additional space is needed when external exhaust elbow is used. Can be 0" clearance

when house exhausting is lined up directiy wilh dryer exhaust.

• In the above illustration, the installation

spacing is in inches and is the minimum
allowable.

• Additional spacing should be considered

for ease of installation and servicing.

• If closet door is installed, the minimum

air openings in top and bottom are

required. Louverecf doors with equivalent

air openings in top and bottom are
acceptable.

• Recessed area and closet installations

recuire a 6-inch minimum clearance

above the laundry center.

• All installations must be exhausted

outside. Use at least the minimum
dimensions indicated.

14