Kenmore 1206 User Manual
Page 24
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Shuttle Assembly
Shuttle Race Cover
Shuttle
Shttle Race
It may be necessary to clean the shuttle area occasionally.
L
Raise
the needle bar to its highest point and remove bobbin case.
2. Push levers sideways of the shuttle assembly and lift shuttle and shuttle race cover out by the center pin.
3. Clean the shuttle race of any lint or small particles of thread with a small brush.
4. Put a drop of oil on the center pin of the shuttle and on shuttle race {see arrows).
To reassemble, hold shuttle by center pin and fit carefully into assembly opposite the shuttle driver.
Slip shuttle race cover into place. Snap the levers into position.
Occasionally, remove the needle plate and clean feed dog with a soft brush.
23