Convert thiovih burner orifices, S convert air, Shuner(s) – GE 49-8338 User Manual
Page 45: Check for le«k, Adjustment, Imqt'a ¥ ¥ at'¥rim ¥mji2*ti^¥tr^'t’frume
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

IMQT'A ¥ ¥ AT'¥riM ¥mJI2*Ti^¥Tr^'T’frUMe
M X - % K ^ -B-iHR a .^,a JiriLJSL:M.S^X ^‘ :JSL±'%k^ M.
JL Ji.^l'^tjy
(continued)
HOW TO COMVERT THE RAHOE FOR USE
WITH IP
m
OR HATURAL GAS (continued)
IS
CONVERT THIOVIH BURNER ORIFICES
@¥©il iyr^@r
1. Remove oven door, storage drawer or broiler
drawer, oven bottom and burner baffle. Tne
lower burner orifice spud is located behind the
storage drawer, broiler drawer or kick panel, (On
some models, a metal shield must be removed to
access the orifice.)
2. To convert to IP gas,
use a
1/2"
wrench to turn
the lower burner orifice
spud clockwise. Tighten the
^ud only until it is snug.
10
prevent damage, do
not overtighten the spud.
To convert to natural gas,
loosen the spud about 2 turns.
§r®il iureier (on some models)
To convert to IP gas, use a 1/2" wrench to
turn the upper burner orifice spud clockwise.
Tighten spud only until it is snug with the base.
To prevent damage, do not overtighten spud.
To convert to natural gas, loosen the spud
iiKmil
9
fiirnc
S CONVERT AIR
adjustment
SHUnER(S)
For IP gas, loosen the
__ _ 1______ I _________ __ J
niimps ucciu si;i cw cum
rotate the shutter to the
full open position. With
baffle in place, flames
should have approximately
1
uxuc:; V/Vxii^o cuxui
should not extend beyond
the edges of the burner baffle. After 30 seconds
of burner operation, check for flames lifting off
burner ports. If lifting is observed, graduaUy
r#»r
1
iir*A air
nr»i»ninrr iinfil fla-miio at*«
A
VAJH
V/jpV'XXUlA^ V4XXLXX XJ.«
p
AXXX>^0 CXX V..'
stabilized.
For natural gas, the shutter should be open
1/2" or about 3/4 of the way open.
[S
CHECK FOR LE«K
When all connections have been made, make sure
all range controls are in the off position and turn
on the main gas supply valve. Use a Uquid leak
detector at all joints and connections to check for
leaks in the system.
CAUnONi DO NOT USE A FlAiVlE TO
CHECK FOR GAS LEAKS.
When using test pressures greater than 1/2 psig
to pressure test the gas supply system of the
residence, disconnect the range and individual
shut-off valve from the gas supply piping. When
using test pressures of 1/2 psig or less to test the
gas supply system, simply isolate the range from
the gas supply system by closing the individual
^££_1_
sjiuL-uii vcuve.
p
m
44