GE CGS980SEMSS User Manual
Cgs980semss, Ge café, 30" free-standing gas range
For answers to your Monogram,
®
GE Profile
™
or
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
®
service,
800.626.2000.
Specification Revised 12/07
230151
You must use the rear filler strip kit shipped with
the range or the optional accessory backguard
when installing these ranges
Note: Cabinets installed adjacent to slide-in
ranges must have an adhesion spec of at least
194° temperature rating.
Installation Information: Before installing, consult
installation instructions packed with product for
current dimensional data.
All GE ranges are equipped with
an Anti-Tip device. The installation
of this device is an important,
required step in the installation
of the range.
Dimensions and Installation Information (in inches)
CGS980SEMSS
GE Café
30" Free-Standing Gas Range
28-1/4*
36
Maintain
at least 6"
from nearest
combustible
surface.
Acceptable
Electrical
Outlet Area
30" Slide-In Range
Dimensions (in inches)
45-1/8
2-1/4
5
6
4-1/2
30
30" Min.
15" Min.
6
30" Slide-in Elec. Range
Aug. 8, 2003 -km
23-3/16
30
30
If you are NOT using the
Filler strip or Backguard:
If you are using the
Filler strip or Backguard:
25
*Wall to front of
closed door handle
on model JSP34.
28" on models
JSP26/JSS26/16.
Note: Range may be placed with 0" clearance (flush) at the back wall and side walls
below countertop if the range side trims above the countertop extend beyond the cabinet
fronts at least 1/4". (Self-clean models only.) Maintain at least 6" distance from nearest
combustible surface.
30
31-1/2
28-1/4*
36
Maintain
at least 6"
from nearest
combustible
surface.
Acceptable
Electrical
Outlet Area
30" Slide-In Range
Dimensions (in inches)
45-1/8
2-1/4
5
6
4-1/2
30
30" Min.
15" Min.
6
30" Slide-in Elec. Range
Aug. 8, 2003 -km
23-3/16
30
30
If you are NOT using the
Filler strip or Backguard:
If you are using the
Filler strip or Backguard:
25
*Wall to front of
closed door handle
on model JSP34.
28" on models
JSP26/JSS26/16.
Note: Range may be placed with 0" clearance (flush) at the back wall and side walls
below countertop if the range side trims above the countertop extend beyond the cabinet
fronts at least 1/4". (Self-clean models only.) Maintain at least 6" distance from nearest
combustible surface.
30
31-1/2
Counter Cutout Dimensions (in inches)
30"
37-1/4"
26-1/4"
46-3/8"
36-1/4"
+_
1/4
9
30
2
4 4
24
13
14-1/2
2-1/2
Recommended area
for thru the floor
connection of pipe stub
and shut-off valve
Recommended common
area for gas outlet and
electrical outlet
Recommended
area for 120V outlet
on rear wall and
area for thru the
wall connection
of pipe stub and
shut-off valve
30"
37-1/4"
26-1/4"
46-3/8"
36-1/4"
+_
1/4
9
30
2
4 4
24
13
14-1/2
2-1/2
Recommended area
for thru the floor
connection of pipe stub
and shut-off valve
Recommended common
area for gas outlet and
electrical outlet
Recommended
area for 120V outlet
on rear wall and
area for thru the
wall connection
of pipe stub and
shut-off valve