Provide adequate gas supply, Mt%0 k:t\mljkji±m. a\jm – GE 49-8338 User Manual
Page 33
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

¥^TOrFiA
T
T
A''T«¥^1^T
nk"rC?^15¥Tr^'T’¥r\'^TC!
MT%0 K:t\MLjKji±M. A\jm
JLl^i3
M
l
M.
(contimied)
LU
PROVIDE ADEQUATE GAS SUPPLY
Your range is designed to operate at a pressure ^
of 4" of water column on natural gas or, if designed
for LP gas (propane or butane),
Vd"
of water
column. Make sure you are supplying your range
with the type of gas for which it is designed. This
range is convertible for use on natural or propane
gas, if you decide to use this range on a different
type of gas, conversion adjustments must be made
by a service technician or other qualified person
before attempting to operate the range on that gas.
For proper operation, the pressure of natural gas
supplied to the regulator must be between 4" and
13" of water column. For LP gas, the pressure
ciir»r»lii»H miict
hpitwfifin
10
"
and
19
/'
nf wfltpr
XJlJ.V4.Wt..
WWVTT
w «.4.A.AVJ.
juv
wj
. «««.«.».'
w
«.
column. When checking for proper operation of
die regulator, the inlet pressure must be at least
1" greater than the operating (manifold) pressure
as given above. The pressure regulator located
at the inlet of the range manifold must remain in
the supply line regardless of whether natural or
LP gas is being used. A flexible metal appliance
connector used to connect the range to the gas
supply line should have an I.D. of 1/2" and b^e
5 feet in length (shorter and longer lengths are
acceptable) for ease of installation. In Canada,
flexible connectors must be single wall metal
connectors no longer than 6 feet in length.
Shut off the main gas supply valve before
disconnecting the old range and leave it off until
new hook-up has been completed. Don’t forget
to relight the pilot on other gas appliances when
you turn the gas back on.
Because hard piping restricts movement of the
range, the use of an A.G.A.-certified flexible
metal appliance connector is recommended
unless local codes require a hard-piped
connection. Never use an old connector when
installing a new range. If the hard piping method
is used, you must carefully align the pipe; the
range cannot be moved after the connection
IS made.
To prevent gas leaks, put pipe joint compound
on, or wrap pipe thread tape with Teflon*
around, all male (external) pipe threads.
*Teflon: Registered trademark of DuPont
Fip@
mi
Ebctils lycatbiis
im
Itfuipped witli Segiedf iarners
This area allows
for flush range
InStQliBtiOn with
through-the-wall
connection of pipe
and rear wall
120V outlet.
Shortest
connection
from hard pipe
stub location to
range hookup.
This area allows for
flush range installation
with
through-the-floor
connection of pipe
stub/shut-off valve.
6as Pipe and Electric Outlet Locations
for ftlodels Equipped with Puai Burners
This area allows
for flush range
installation with
through-the-wall
connection of pipe
stub/shut-off valve
and rear wall
120 V outlet.
Shortest
connection
from hard pipe
stub location to
range hookup.
This area allows
for flush range
installation with
through-the-fioor
connection of pipe
stub/shut-off valve.
32