beautypg.com

2100_12_bck.pdf, Store this booklet for future reference, Troubleshooting – Braeburn 2100 User Manual

Page 7: Wiring diagram, Symptom potential solution

background image

12

TROUBLESHOOTING

6

cont.

WIRING DIAGRAM

7

SYMPTOM

POTENTIAL SOLUTION

Fan continues to run
all the time whether
the system is on
or off.

Check that the fan control switch is in the

AUTO position. This

will allow the fan to run only when the heating or cooling system

is turned on and running.
Check thermostat wiring to make sure that the fan control

wiring is connected to the correct terminals on the wiring

terminal block. See Installation and Wiring Diagram sections of

this manual.

The room is too
warm or too cold.

See Review Set Temperature section of this manual to verify the

current set point and make any modifications that are necessary.

Thermostat is in Adaptive Recovery Mode- (see section 5.6).

System turns on
prior to the end of a
setback period.

1st Stage

Heat Relay

Wiring Diagram for 2 Stage Heat, 1 Stage Cool

Tr

an

sf

or

m

er

C

om

m

on

(R

eq

ui

re

d)

120 VAC

R

0

B

C

Y

W1

G

W2

Auxiliary Heat

Relay (Stage 2)

Fan

Relay

24 VAC

Neutral

Hot

Compressor

Contact

Store this

booklet for

future reference

Braeburn Systems LLC warrants each new Braeburn thermostat against any defects that are

due to faulty material or workmanship for a period of five years after the original date of

purchase by a professional service technician. This warranty and our liability does not apply to

batteries, nor does it include damage to merchandise or the thermostat resulting from

accident, alteration, neglect, misuse, improper installation or any other failure to follow

Braeburn installation and operating instructions.
Braeburn Systems LLC agrees to repair or replace at its option any Braeburn thermostat

under warranty provided it is returned postage prepaid to our warranty facility in a padded

carton within the warranty period, with proof of the original date of purchase and a brief

description of the malfunction. This limited warranty does not include the cost of removal or

re-installation.

This warranty gives you specific legal rights and you may also have other rights that vary from

state to state or province to province. Answers to any questions regarding our limited warranty

may be obtained by writing our corporate offices.

WARRANTY FACILITY: Braeburn Systems LLC

Attn: Warranty Department

2215 Cornell Avenue

Montgomery, IL 60538

Braeburn Systems LLC, as an ENERGY STAR

®

partner,

has determined that this product meets the ENERGY STAR
Guidelines developed by the U.S. Environmental Protection
Agency and the U.S. Department of Energy for maximum
energy efficiency.

For more information on energy

savings, go to

www.energystar.gov

© 2005 Braeburn Systems LLC • Patents Pending • All Rights Reserved. No. 2100-100-004

Braeburn Systems LLC
2215 Cornell Avenue • Montgomery, IL 60538
Technical Assistance: www.braeburnonline.com
Call us toll-free: 866-268-5599 (U.S. Only)
630-844-1968 (Outside the U.S.)