2100_4_5.pdf, Programming – Braeburn 2100 User Manual

Page 3

background image

4

5

4.2

Setting Current Time of Day and Day of Week

NOTE:

It is important for you to set the current time of day (note AM/PM indicator in

display), and the current day of week correctly to avoid problems with program execution.

PROGRAMMING

4

4.1

Default Thermostat Settings

Function

Status After Reset

Operation Mode

Normal Operating Mode

Temperature Hold

Permanent and Temporary Hold Cleared

Clock

12:00 pm, Monday

Room Temperature

70˚ F (21.0˚ C), to be renewed within

5 seconds

Setpoint Temperature

According to system switch:

62˚ F (17.0˚ C) for Heat and Off

83˚ F (28.0˚ C) for Cool

Temperature Scale

˚F or ˚C dependent on switch setting

Operating Program

DAY program, Monday

Low Battery Warning

Off, to be renewed within 5 seconds

First Stage Differential

0.5˚ F (0.25˚ C)

Second Stage Differential

2˚ F (1.0˚ C)

Short Cycle Protection Timer Reset

Output Relays

Off

Filter Check Monitor

0 days-off

Extended Hold

Indefinite

Adaptive Recovery Mode

Reset

NOTE:

The thermostat will return to normal operating mode automatically after 15

seconds if no key is pressed. It will also return to normal operating mode immediately if

the RETURN button is pressed.

NOTE:

Once you have finished setting the temperature differentials, you can wait 15

seconds and the thermostat will automatically return to the normal operation mode.

Otherwise, you can press the RETURN to set the Extended Hold Time.

1. When in normal operating mode, press the

DAY/TIME keypad button. The LCD display will be

cleared except for the time, am/pm indicator and

the day of the week. The hour portion of the

time will flash.
2. Press the or button to set the current hour.
3. Press the DAY/TIME button again, the minute portion of the time will flash.
4. Press the or button to set the current minute.
5. Press the DAY/TIME button again, the day of the week indicator will flash.
6. Press the or button to set the current day of the week.
7. Press the DAY/TIME button again and the thermostat will return to normal operating mode.

4.3

Setting Thermostat User Options

The default user options are compatible with most systems and applications. They are normally

set at the time of installation and usually do not require modification under normal operating

conditions. If you desire to change these settings, simply follow the instructions below.

The default setting is 0.5˚ F (0.25˚ C). The room temperature must change 0.5˚ F (0.25˚ C) from

the setpoint temperature before the thermostat will initiate the system in heating or cooling.

The default setting is 2˚ F (1.0˚ C). This means that the room temperature must change 2˚ F

(1.0˚ C) in addition to the first stage differential setting before the thermostat will initiate the

second stage of heating.

Setting the First Stage Temperature Differential

Setting the Extended Hold Time (see also section 5.3)

The default setting is Long (indefinite) Hold. If the HOLD feature is activated, the current

setpoint will be held until HOLD is released.

1. After pressing the RETURN button again, the

display will show "

HOLD LG", where LG is

indefinite hold.
2. Press the or button to change the

Extended Hold time from indefinite (

LG) to

24 hours (

SH).

3. Press the RETURN button again to set the Filter Check Monitor or wait 15 seconds for

the thermostat to return to the normal mode.

4.3

Setting Thermostat User Options

cont.

HOLD

Setting Filter Check Monitor (see also section 5.7)

The default setting is 0 days (Filter Monitor disabled).

FILT

NOTE:

The temperature differential settings are the same for both the heating and

cooling systems.

4.3.1

1. In normal operating mode, press and hold the RETURN

button for 4 seconds. The LCD display will show "

d1 x",

where "

x" equals the ˚F / ˚C differential setting. This is

the current temperature differential setting.
2. Press the or button to set the temperature

differential to your desired setting of 0.5˚, 1˚, or 2˚ F

(0.25˚, 0.5˚, or 1˚ C).

PROGRAMMING

4

cont.

Setting the Second Stage Temperature Differential

4.3.2

1. Press and hold the RETURN button again and the

LCD display will show "

d2 x", where "x" equals

the ˚F / ˚C differential setting. This is the current

second stage differential setting.
2. Press the or button to set the second stage

differential to your desired setting of 2˚, 3˚, 4˚, 5˚,

or 6˚ F (1.0˚, 1.5˚, 2.0˚, 2.5˚, or 3.0˚ C).

4.3.3

4.3.4

1. After pressing the RETURN button again, the display will show "FILT XXX SET"

where

XXX is the Filter Monitor interval.

2. Press the or button to change the Filter Monitor

interval to the desired value of 0 (disabled), 30, 60, 90,

120, or 180 days.

3. Press the RETURN button or wait 15 seconds for the

thermostat to return to the normal mode.