A&D Weighing FS-30Ki User Manual
Page 23

21
 
FS-30Ki / d=0.01 kg 
UPPER & LOWER LIMIT WEIGHT SETTING MODE 
(F07-0) 
Target weight = 5.00 kg. 
HI = 10.10 kg, LO = 9.91 kg 
 
 
 
 
 
 
 
 
 
 
 
 
 
Outside the range of the analog sweep display
FS-30Ki / d=0.01 kg 
TARGET WEIGHT SETTING MODE 
(F07-1 or F07-2) 
Target weight = 5.00 kg. 
HI = 0.10 kg, LO = 0.09 kg 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
-
000
10.20
Within the limits
Above the upper limit
-
000
10.00
-
0000
9.80
Lower limit
Below the lower limit
Upper limit
-
0000
0.00
NET
◄
ZERO ◄
Lower than range
Below the lower limit
Above the upper limit
-
0000
5.43
Higher than range