Analog sweep display, 1. selecting a display mode – A&D Weighing FS-30Ki User Manual
Page 21

19
9. ANALOG SWEEP DISPLAY
The FS-i series has a 60 segments analog sweep display. The DISP. key switches 
its display mode. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
It is possible to specify the display mode that will be shown first when the power is
switched on. See the Function F16.
Use the analog sweep display with positive target and limit weights.
 
 
9-1. Selecting a display mode
Simple weighing display mode
The 60 segments represent zero to full scale. When the scale is in the net mode, the 
analog sweep display shows net weight. 
In the TARGET WEIGHT SETTING MODE (F07-1 or F07-2), the target weight will be 
shown on the display as a flashing segment. 
The UPPER & LOWER LIMIT WEIGHT SETTING MODE (F07-0) does not show
the target weight segment.
Target weighing display mode
The 60 segments represent zero to full scale. When the scale is in the net mode, the 
analog sweep display shows net weight. 
In the TARGET WEIGHT SETTING MODE, the 40th segment will flash as the target 
weight. Thus the 60 segments represent the relative weight that the target weight is 
scaled to the 40 segments. 
As the weight increases, the analog segments approach the flashing segment. This 
will provide a simple way of filling the container to the target weight. 
The UPPER & LOWER LIMIT WEIGHT SETTING MODE (F07-0) does not have
this display.
Limit check weighing display mode
The display shows comparison limits and results. The lower limit is shown at the 21st 
segment flashing and the upper limit is shown at the 40th segment flashing. The 
results will be known by the segments turned on. 
Limit check weighing display
Simple weighing display
Target weighing display
Analog display OFF
Except the UPPER & LOWER 
LIMIT WEIGHT SETTING MODE 
(F07-0).