Operation and Function

z

For the SJ-F2000 series, SJ-F5010
Connect the power supply. The power turns on automatically.

z

For the SJ-F5000 series (Except SJ-F5010)
Connect the power supply, and then turn on the power switch of the blower.

Static elimination starts or stops when the START/STOP button is pressed and held down for
approx. 1 second during operation.
The indicator turns on when static elimination is interrupted, as shown below.

* The airflow stabilizes approx. 20 seconds after operation starts.

To save energy when 24 V DC voltage is connected between rear terminals [4] and [5], static
elimination and the fan can be interrupted while the power is on.

See "Input/output circuit and the wiring method (SJ-F2010/5010 only)" (page 2).

Adjust the airflow by using the

or

cursor keys.
The indicator LED flashes in response to the
airflow change.

After you release the cursor key, the set value indicated by the LED flashes for approx. 5 seconds
and returns to the display that indicates the electric charge level. To set the airflow to the initial
value, press and hold down both cursor keys simultaneously for approx. 2 seconds.

Confirms the electric charge level of the target.
The plus and minus side LEDs of the indicator will illuminate in response to the current charge
level of the target.
The further away from the center the illuminated LED is, the higher the electric charge level.
When static elimination is finished, the green LED in the middle of the indicator will be illuminated.

The LED illuminates or flashes to indicate the current status.
SJ-F2010/5010 outputs the signal from the rear input/output terminal block.
The main indicator displays any decreases or abnormalities in ion generation.

„

Display and output specifications

Returns all of the settings to the factory defaults. While pressing the

and

cursor keys simultaneously,

turn on the power. The indicators illuminate, as shown below. Release the keys to start operation.

While using the keylock function, operations other than using the START/STOP buttons can be
locked to prevent the accidental operation of buttons.
While pressing the cursor

key, turn on the power. The indicators illuminate, as shown below.

After you release the cursor key, the display switches to the electric charge level display and
static elimination begins. To turn keylock off, repeat the above procedure.
* Operate with the front cover closed.

The alarm, the ion level alarm, and the condition alarm are turned on and off manually. (to verify

output terminal operation)

While pressing the START/STOP button and the

and

cursor keys simultaneously, turn on

the power. The indicators illuminate, as shown below.

For various outputs, while pressing the

cursor key, turn on the power, and while pressing the

cursor key, turn off the power. Static elimination is interrupted while output is being verified.

Power ON again to restart static elimination.
* Operate with the front cover closed.

The PNP and NPN output are used to switch the output circuit. The initial setting is NPN.
* Operate with the front cover closed.
• NPN

While pressing the

cursor key and the

START/STOP button simultaneously, turn on the
power.
Release the buttons to start static elimination.

• PNP

While pressing the

cursor key and the

START/STOP button simultaneously, turn on the
power.
Release the buttons to start static elimination.

Maintenance of Electrode Probes

When the SJ-F2000/5000 Series is used for a long period, the electrode probes become dirty due

to the accumulation of dust.

If you continue to use the SJ-F2000/5000 Series with dust accumulating on the electrode probes,

the static elimination ability may deteriorate, resulting in an accident or product breakdown.

Therefore, be sure to clean the electrode probes periodically.

„

Cleaning the electrode probes

Use a cotton swab soaked in alcohol to softly wipe the electrode probes.

1

Slide the lock switch located on the face of the
front cover. After you slide the lock switch,
press the tab at the upper part of the front
cover, and then pull the front cover towards
you to remove it.

2

Push the stopper, which is to the right of the
slot, towards the outside. This is the stopper
used to set the board for the electrode probes.
Pull out the board for the electrode probes.

* To mount the board, perform the above procedure in

the reverse order.

For the power source, use a DC power supply with sufficient marginal output

at a rated voltage of 24 V (output capacity per each blower must exceed the

following values; SJ-F2000: 0.9 A, SJ-F2500: 1.2 A, SJ-F2010: 1.0 A, SJ-F5010:

1.9 A).

Before using the unit, wait approx. 20 minutes after the unit is turned on.

Otherwise, the ion balance may not be stabilized.

Power on

Start/stop static elimination

Static elimination starts automatically when the power is turned on.

External interruption of static elimination (SJ-F2010/5010 only)

Control the airflow

Reduces airflow

Increases airflow

Press and hold down

or

to continue adjusting the

airflow.

Electric charge level display function

Alarm output/display function

[1]

[2]

[3]

[4]

[5]

[6]

[7]

. For SJ-F2010/5010

Connect a DC24 V power supply (Class 2 or LPS) with sufficient output capacity to the power terminals ([2] and [3]).

NOTICE

Point

Reference

.

SJ-F2500/SJ-F5500

.

SJ-F2000/SJ-F2010/SJ-F5000/SJ-F5010

Reference

. For SJ-F2000/SJ-F5000/SJ-F2010/SJ-F5010

Red

Red Orange Green Orange Red

Red

Red Orange Green Orange Red

Status

Static elimination
interruption input

Indicator

Condition/ion

level alarm

indicator

Alarm

output

Ion level

condition

alarm output

Power OFF

-

-

-

OPEN

OPEN

Normal operation

Open

Indicates the

electric charge level

Turn off

Short

OPEN

Static elimination
interrupted

Short

Left and right edge

red LED illuminate

Turn off

OPEN

OPEN

Ion amount decreased

-

Indicates the

electric charge level

Red LED flashes

(ON OFF ON OFF)

Short

Short

Condition abnormal

-

Indicates the

electric charge level

Red LED flashes

(ON ON OFF ON ON OFF)

Short

Short

Ion amount decreased
and condition abnormal

-

Indicates the

electric charge level

Red LED flashes
(ON OFF ON OFF)

Short

Short


Front cover removed

-

Three middle LEDs flash

(ON OFF ON OFF)

Turn off

OPEN

OPEN


Internal memory value abnormal
Abnormal discharge Fan damaged

-

All LEDs flash

(ON OFF ON OFF)

Turn off

OPEN

OPEN

Initialization

Keylock function

Output verification (SJ-F2010/5010 only)

NPN/PNP output switching (SJ-F2010/5010 only)

Maintenance of electrode probes

• Turn off the SJ-F2000/5000 Series before the maintenance of the electrode probes.

• Do not touch the electrode probes directly with your hand or fingers, as

this may cause injury. Be extremely careful when cleaning them.

Be sure to mount the electrode probes so that they are facing in the correct

direction, as described here.

· SJ-F2500/SJ-F5500

· SJ-F2000/SJ-F2010/SJ-F5000/SJ-F5010

. Keylock ON

. Keylock OFF

CAUTION

NOTICE

Push the stopper
towards the outside.

Pull out the
board.