beautypg.com

Mirror assembly adjustment – Inovonics FA206DS User Manual

Page 3

background image

© 1996 Inovonics Wireless Corporation

3

02154b.doc LIT-FA206DS-INSTALL hc:7-Aug-01

Mirror Assembly Adjustment:

!" Set Vertical angle based on the following table. The table indicates setting for mirror type, mounting

height and desired range. Vertical angle calibration markings are on the mirror. Slide the mirror forward
or back until the angle hash marks are in line with the markers on each side of the frame.


Mounting

Height

Broad Mirror

30'(9m) 50'(15m)

Barrier Mirror

50'(15m) 80'(25m)

Long Range Mirror

80'(25m) 120'(36m)

6'6"(2m)

-6

# -3# -3# -2# -2# -1#

7'6"(2.3m)

-8

# -5# -5# -3# -3# -2#

8'6"(2.6m)

-9

# -6# -6# -4# -4# -2#



0

-8

-16

+2

0

-8

-16

+2

0

-8

-16

+2


!" Adjust Horizontal angle of the mirror assembly, if necessary. Rotate the assembly from side to side until

aimed in the desired direction.


!" After the unit has been programmed and installed, follow instructions for setup and walk testing the unit.

Range and coverage can be adjusted by changing mirror angle setting.


!" Optional accessories including the B328 Gimbal Mount and the B335 Low Profile Mount permit the

FA206DS to be mounted in many locations and aimed to permit desired coverage.