beautypg.com

Inovonics FA203S User Manual

Inovonics Communication

background image

FA203S (Single-button) / FA203D (Double-button) Pendant Transmitter

INSTALLATION INSTRUCTIONS

02151D

Important Notes

Intended use: Portable transmitters for emergency or
non-emergency applications. Not weatherproof.

Pendants are designed to be installed and maintained by
professional security technicians.

Inovonics advises that FA203s always be supervised.

Pendants should also be tested at least once per week.

© 1999 Inovonics Wireless Corporation

Louisville CO

(800) 782-2709

www.inovonics.com

02151D.FM lit-fa203-install

hc:30-Sep-02

1. Enter programming mode on system receiver or panel.

Select recommended transmitter options (see below).
When instructed to connect the transmitter, open the trans-
mitter case by prying the slot behind the LED. Install bat-
tery, if necessary.

2. Connect the programming cable from the programming

device to the programming header on the transmitter.

3. Press the Reset button on the transmitter.
4. Disconnect the programming cable.
NOTES: (a) FA401 and FA404 receivers program directly
from the receiver. FA416 and FA464 receivers have default
programming options or can be customized with the FA116
programmer. Panel security systems: see system instructions.
(b) FA-series transmitters retain programming data in non-
volatile memory. They do not require reprogramming after
loss of power. When installing new battery, press reset button
to re-initialize the transmitter and restore programming.
(c) Transmitters should always be programmed for supervi-
sion.

Dimensions:

3 x 1.6 x0.72"

Typical battery life:

3 to 5 years

Battery (BAT608):

3.0V lithium Panasonic CR2
(or approved equivalent)

For information on supervision options, request Tech
Notes TN1025 and TN1031.

To activate the FA203S, press and hold the FA203S button. To
activate the FA203D, press and hold both FA203D buttons
simultaneously
Alarm signals are transmitted multiple times, and are indicated
by the blinking transmission indicator LED. Holding the button
results in continuous alarm transmission.
When the buttons are released, the FA203 will send an alarm
restoral signal.

ATTENTION: Test transmitter at least once per week.

External contacts:

N/O

EOL resistor:

No

Internal contact:

No

Suggested check-in interval: 60 seconds

* To extend battery life, actual check-in interval is about two-and-
one-half times the programmed value.

If desired, the FA203 can be screw-mounted to a fixed surface.
Drill through-holes (.200" max diameter) in the back housing
cover in locations indicated.
Wood screws used to mount the transmitter should be size #8 or
smaller.
Screw head height must be less than .150". Larger screw heads
may cause short-circuits on the unit.

Caution: Pendant Chain Safety

The beaded pendant chain is designed for user safety. The
chain will break when subjected to sudden or extended stress,
reducing potential injury to the wearer. In most cases, the
chain will separate at the connector, and can easily be re-
assembled by snapping the end bead back into the connector.
The chain can also be adjusted by cutting to the desired
length.

WARNING: Substitution of stronger cords or chains may
result in injury to the wearer.

Transmission Indicator LED

FA203

FA203

Programming Header

Reset Button

Batte ry

Programmin

Specifications

Operation

Factory Defaults / Recommended Programming

Optional Fixed-Position Mounting

Printing Instructions

1. Print Duplex

a. Align and orient back page to

match front page.

2. Cut on dashed line
3. Fold cutsheet in half along the

8.5" axis.

Call Roger @ 303.939.9336, Ext 117

This manual is related to the following products: