INSTALLATION INSTRUCTIONS
02151D
Important Notes
Intended use: Portable transmitters for emergency or
non-emergency applications. Not weatherproof.
Pendants are designed to be installed and maintained by
professional security technicians.
Inovonics advises that FA203s always be supervised.
Pendants should also be tested at least once per week.
© 1999 Inovonics Wireless Corporation
Louisville CO
(800) 782-2709
www.inovonics.com
02151D.FM lit-fa203-install
hc:30-Sep-02
1. Enter programming mode on system receiver or panel.
Select recommended transmitter options (see below).
When instructed to connect the transmitter, open the trans-
mitter case by prying the slot behind the LED. Install bat-
tery, if necessary.
2. Connect the programming cable from the programming
device to the programming header on the transmitter.
3. Press the Reset button on the transmitter.
4. Disconnect the programming cable.
NOTES: (a) FA401 and FA404 receivers program directly
from the receiver. FA416 and FA464 receivers have default
programming options or can be customized with the FA116
programmer. Panel security systems: see system instructions.
(b) FA-series transmitters retain programming data in non-
volatile memory. They do not require reprogramming after
loss of power. When installing new battery, press reset button
to re-initialize the transmitter and restore programming.
(c) Transmitters should always be programmed for supervi-
sion.
Dimensions:
3 x 1.6 x0.72"
Typical battery life:
3 to 5 years
Battery (BAT608):
3.0V lithium Panasonic CR2
(or approved equivalent)
For information on supervision options, request Tech
Notes TN1025 and TN1031.
To activate the FA203S, press and hold the FA203S button. To
activate the FA203D, press and hold both FA203D buttons
simultaneously
Alarm signals are transmitted multiple times, and are indicated
by the blinking transmission indicator LED. Holding the button
results in continuous alarm transmission.
When the buttons are released, the FA203 will send an alarm
restoral signal.
ATTENTION: Test transmitter at least once per week.
External contacts:
N/O
EOL resistor:
No
Internal contact:
No
Suggested check-in interval: 60 seconds
* To extend battery life, actual check-in interval is about two-and-
one-half times the programmed value.
If desired, the FA203 can be screw-mounted to a fixed surface.
Drill through-holes (.200" max diameter) in the back housing
cover in locations indicated.
Wood screws used to mount the transmitter should be size #8 or
smaller.
Screw head height must be less than .150". Larger screw heads
may cause short-circuits on the unit.
Caution: Pendant Chain Safety
The beaded pendant chain is designed for user safety. The
chain will break when subjected to sudden or extended stress,
reducing potential injury to the wearer. In most cases, the
chain will separate at the connector, and can easily be re-
assembled by snapping the end bead back into the connector.
The chain can also be adjusted by cutting to the desired
length.
WARNING: Substitution of stronger cords or chains may
result in injury to the wearer.
Transmission Indicator LED
FA203
FA203
Programming Header
Reset Button
Batte ry
Programmin
Specifications
Operation
Factory Defaults / Recommended Programming
Optional Fixed-Position Mounting
Printing Instructions
1. Print Duplex
a. Align and orient back page to
match front page.
2. Cut on dashed line
3. Fold cutsheet in half along the
8.5" axis.
Call Roger @ 303.939.9336, Ext 117