After scale is completely powered up, it is ready to weigh loads.
Zero
Action
To Z
ERO
the scale, press ZERO button on scale or
on remote controller.
Function
Scale sets current load to be Z
ERO
, as if it has no load.
The ZERO indicator
lights on.
The weight reading turns “0”, (or “0.0” or “0.00”, depending on the resolution).
Condition
;
The scale must not be in H
OLD
mode. Otherwise, error message
will keep
flashing.
;
The scale must be stable. Otherwise, error message
will flash.
;
Current weight reading is in M
ANUAL
‐Z
ERO
R
ANGE
. Otherwise, error message
will flash.
To learn more about Manual‐Zero Range, please refer to Scale Configuration function.
Tare In
Action
To T
ARE
I
N
a tare weight into scale, press TARE button on scale or
on remote
controller (when the scale is in G
ROSS
M
ODE
).
Function
The scale stores a tare weight, and shifts to N
ET
M
ODE
. All subsequent readings are
deviations from the tare value.
The TARE indicator
lights on.
The weight reading turns to “0” (or “0.0” or “0.00”, depending on the resolution).
Condition
;
The scale must not be in H
OLD
mode. Otherwise, error message
will keep
flashing.
Z
ERO
T
ARE
I
N