Page 14 of 24

;

The scale must not be in H

OLD

 mode. Otherwise, error message 

  will keep 

flashing.   

;

The scale must be in G

ROSS 

M

ODE

. Otherwise, error message 

  will flash.   

Please flip to System Unit of Scale Configuration in 6 Advanced Operation section in 

Technical Manual for more information about scale’s measurement system. 

Tare Set 

Action 

Press 2ND button on scale or 

  on remote controller, and TARE button on scale or 

 

on remote controller in turn (when the scale is in gross mode), to enter T

ARE 

S

ET

 function.   

Press ZERO and TARE button on scale or 

  and 

  on remote controller to input the 

digits. 

Press HOLD button on scale or 

  on remote controller to confirm the input value. 

Function 

The scale stores the tare weight that user inputs, and shifts to N

ET 

M

ODE

. All subsequent 

readings are deviations from the tare value. 

The screen displays “00000” (or “0000.0” or “000.00”, depending on the resolution) with 

the first “0” flashing, waiting for user’s input.   

To learn how to input digits, please refer to 5 User Input section. 

Condition 

;

The scale must not be in H

OLD

 mode. Otherwise, error message 

  will keep 

flashing.   

;

The scale must be in G

ROSS 

M

ODE

. Otherwise, error message 

  will flash.   

;

The input tare weight must be greater than 0 (or 0.0 or 0.00, depending on the resolution). 

Otherwise, error message 

  will flash. 

;

The input tare weight must be lesser than scale’s maximum capacity. Otherwise, error 

message 

  will flash. 

T

ARE

S

ET

NOTICE:

Tare setting will reduce the apparent overloading range of the scale.

For example, if a 1000kg is set by tare set function, and the scale

maximum capacity is 5000kg, the scale will overload at a new weight of

4009kg (5000 – 1000 + additional 9 divisions).

NOTICE:

D

ISPLAY

U

NIT

S

WITCH

function only changes the unitScale does not save

this setting unless S

YSTEM

U

NIT

is changed.