beautypg.com

Battery – Holtgreven USED OCS-B 40,000 lb (x 20) User Manual

Page 24

background image

OCS User Guide

Page 21 of 24

 

7. Battery

To maximize the battery life, please note the following battery maintenance guide. 
 
  This scale is powered by a 6V rechargeable lead‐acid battery.   
  The battery is permanently attached to the battery door. To remove the battery pack, turn off the two screws on 
the access door, pull the battery pack straight out, and unplug the battery cable from the scale. 
  The battery works from 80 hours to 200 hours (depending on LED display brightness setting), before requiring 
recharging.   
  In order to conserve battery life, the scale includes an A

UTO 

P

OWER

‐O

FF

 function which senses operational status 

for no activity after certain minutes that user sets, and turns the scale off. An additional battery saving feature is the 

auto I

DLE

 function. This feature preserves battery life by dimming the display after specified minute of no scale 

activity.   
  Charging time for a completely discharged battery is approximately 6 hours.   
  To obtain maximum service life from your batteries, they should be stored between ‐20°C (‐4°F) and +50°C (122°F). 
Stored batteries should be recharged every three months. Battery is fully charged when the status indicator is red.