Parameters for the hi 1756-ws (-2ws) module, Parameters for the hi 1756-ws (-2ws) module -8 – Hardy HI 1756-2WS User Manual
Page 36

HI 1756-WS WEIGH SCALE MODULE
4-8
Parameters for the HI
1756-WS (-2WS)
Module
NOTE:
The Glossary at the end of this manual provides addi-
tional information about the parameters and other
common weigh process definitions.
All parameters in Table 4-1 are either type DINT (4-
byte integer) or REAL (4-byte floating point).
STATUSCMDERROR
0x4000
Output Table Command Failed
STATUSCHANENABLED
0x8000
Set if channel is enabled
Word
Number
Definition
#
Type
Parameter
Description
1
DINT
ChanActive
Flag, determines if a channel is alive.
Legal values are: 0 (Channel Off) or 1
(Channel On)
2
DINT
calyear
Year of last Calibration*
3
DINT
calmonth
Month of last Calibration*
4
DINT
calday
Day of last Calibration*
5
DINT[2
]
calid[2]
ID of calibrator using initials. e.g. JB*
6
DINT
CalibType
Read Only
Button = 3
C2 = 1
Hard Cal = 0
Never Calibrated = FFFF
7
REAL
tareweight
Tare weight in lbs or kgs as determined
by Metric.
8
DINT
Metric
Report weight in lbs or kgs.
Legal Values
lbs = 0
kgs = 1
TABLE 4-1: PARAMETERS