Chapter 2 - specifications, A brief description of chapter 2, Maximum installed modules – Hardy HI 1769-2WS User Manual
Page 15: Channels, Conversion rate, Averages, Resolution, Input, Non-linearity, Waversaver

Chapter 2 - Specifications
2-1
CHAPTER 2 - SPECIFICATIONS
A Brief Description of
Chapter 2
Chapter 2 lists the specifications for the HI 1769-WS
& HI 1769-2WS Weigh Scale Modules. Specifica-
tions are listed for the standard instrument and for
optional equipment. The specifications listed are
designed to assist in the installation, operation and
troubleshooting of the instrument. All service person-
nel should be familiar with this section before
attempting an installation or repair of this instrument.
Specifications for a
Standard HI 1769-WS
Weigh Scale Module
Maximum Installed
Modules
8 modules - per power supply in a single bank (Mod-
ule(s) must be installed within 4 slots on either side of
the power supply)
Channels
1 Channel
HI 1769-WS
2 Channel
HI 1769-2WS
Conversion Rate
100 updates per second
Averages
1-255 User Selectable in single increments
Resolution
Internal:
1:8,388,608
Input
Up to four (4) 350 ohm Full Wheatstone Bridge,
Strain Gauge Load Sensors/Cells (5 volt excitation)
on one vessel.
Non-Linearity
0.0015% of Full Scale
WAVERSAVER
®
User Selectable
•
4.00 Hz
•
2.00 Hz
•
1.00 Hz (Default)
•
0.50 Hz
•
0.25 Hz
•
OFF
Common-Mode
Rejection
120dB from 59 to 61 Hz