Canon EOS Rebel XT User Manual
Page 164
Specifications
164
AF-assist beam:
Small series of flashes fired by built-in flash
Effective range: Approx. 4.0m/13.1ft. at center, approx.
3.5m/11.5ft. at periphery
• Exposure Control
Metering modes:
35-zone TTL full aperture metering
• Evaluative metering (linkable to any AF point)
• Partial metering (approx. 9% of viewfinder at center)
• Center-weighted average metering
Metering range:
EV 1 - 20 (at 20°C/68°F with 50mm f/1.4 lens, ISO 100)
Exposure control:
Program AE (Full Auto, Portrait, Landscape, Close-up,
Sports, Night Portrait, Flash Off, Program), shutter-
priority AE, aperture-priority AE, depth-of-field AE,
manual exposure, E-TTL II autoflash
ISO speed:
Basic Zone modes: Automatically set (ISO 100 - 400)
Equivalent to ISO 100, 200, 400, 800, 1600
Exposure compensation: Manual: ±2 stops in 1/3- or 1/2-stop increments (can be
combined with AEB)
AEB: ±2 stops in 1/3- or 1/2-stop increments
AE lock:
Auto: Applied in One-Shot AF mode with evaluative
metering when focus is achieved
Manual: By AE lock button in all metering modes
• Shutter
Type:
Electronically-controlled, focal-plane shutter
Shutter speeds:
1/4000 to 30 sec. (1/3- and 1/2-stop increments), bulb,
X-sync at 1/200 sec.
Shutter release:
Soft-touch electromagnetic release
Self-timer:
10-sec. delay
Remote control:
Remote Switch RS-60E3
Remote Controller RC-5/RC-1
• Built-in Flash
Type:
Retractable, auto pop-up flash
Flash metering:
E-TTL II autoflash
Guide No.:
13/43 (ISO 100, in meters/feet)
Recycle time:
Approx. 3 sec.
Flash-ready indicator:
Flash-ready icon lights in viewfinder
Flash coverage:
17mm lens angle of view
FE lock:
Provided
Flash exposure compensation: ±2 stops in 1/3- or 1/2-stop increments