beautypg.com

Usb/midi-to-cv/gate a-190-4, System a-100, Doepfer – Doepfer A-190-4 MIDI/USB-CV/Gate/Sync Interface User Manual

Page 16: 6 initialise function ini

background image

USB/Midi-to-CV/Gate A-190-4

System A-100

DOEPFER

16

4.3.6 INITIALISE Function InI

You may want to erase all your parameter settings and
reset the values back to their defaults. If so, please use
the Initialise function.

Please navigate to the Initialise function with the ”>/+“ and
” buttons.

• Hit ”

”. The display shows no The ”>/+“ button

flashes.

• Hit “

“ again or ”

2 “ to cancel the Initialise

function.

• Hit ”>/+“ to initialise all parameter settings to the
values shown in the following chart.
To confirm the store function, the display shows YES
for a short moment.

The following chart shows the initial parameter values:





Parameter

Value Notes

CHANNEL

1

MIDI channel #1

REF. NOTE

24

#24 / Note C2

CLOCK TIME

1

clock frequency at clock output
= MIDI clock frequency

CLOCK POLARITY

PoS

positive

RETRIGGER

0

legato - ie. no retrigger

LFO FREQ.

006

LFO AMPL.

0

LFO off

PORTAMENTO 0

no

portamento

BEND WIDTH

12

1 semitone

ASSIGN CV2

vEI

velocity

ASSIGN MODE

Hig

highest note

GATE POLARITY

PoS

positive

RTRIG. TIME

0

off

CV CHAR.

U-O

1 V / octave