4 storing the tension values, 1 recalling the stored tension values – Checkline MST User Manual
Page 13
13
Requirement:
- Tension meter switched on as described in Chapter 3.2.1.
You can end recall any time by pressing the POWER key.
To recall the tension values:
- Press the RECALL key.
The DISPLAY blinks, showing
22
CN
the average value of the measuring period
and the symbol.
- Press the RECALL key.
The DISPLAY blinks, showing
23
CN
the last value of the measuring period.
- Press the RECALL key.
The DISPLAY blinks, showing
24
CN
the maximum value of the measuring period
and the symbol.
- Press the RECALL key.
The DISPLAY blinks, showing
21
CN
the minimum value of the measuring period
and the symbol.
3.4 Storing the Tension Values
The tension meter features a data logger which stores the following data obtained during
a measuring period:
Average value,
Last value,
Maximum value
(MAX),
Minimum value
(MIN),
Minimum peak value
(MIN PEAK)
(lowest single value measured),
Maximum peak value
(MAX PEAK)
(highest single value measured).
The measured data remain stored in the MST memory even after the instrument is
switched off.
Requirements:
- Tension meter switched on as described in Chapter 3.2.1.
- UPPER or LOWER THREAD inserted as described in Chapter 3.3.
To store the tension values:
- Press the MEM key to start the measuring period.
While the tension data are stored, the MEM
3
cN
Mem
indicator blinks on the DISPLAY
and the currently measured value is displayed.
- When you want to end the measuring period, press the MEM key 4 once again.
Data logging is stopped.
The DISPLAY shows
3
cN
Mem
MEM and the current reading.
3.4.1 Recalling the Stored Tension Values