Checkline FGS-100PV User Manual
Page 7
7
1. A Speed: Changes the left movement or upward speed (Continuous and Program Mode).
2. B Speed: Changes the right movement or downward speed. (Continuous and Program Mode).
3. Speed: Selects speed control knob A or B.
4. Length, Speed or Cycle Display: Displays length, speed or cycle of a program when power is on.
Note: Cycle Display can only be selected in mode SING, CONT or PROG.
5. No: Displays program cycle (0-9).
6. : Indicates high limit value in all modes.
7. : Indicates low limit value in all modes.
8. TIME: Displays programmed delay time between program cycles.
9. LENGTH, SPEED, or Cycle: Selects display of length, speed or cycle of a program.
10. LED LENGTH Indicator: Indicates that length is being displayed.
11. LED SPEED Indicator: Indicates that speed is being displayed. Cycle display is indicated when
both Length and Speed LED’s are off.
12. ZERO: Resets length measurement to zero.
13. LIMIT LED: Indicates one of the manual limit switches has been tripped.
14. OVERLOAD LED: Indicates that the force gauge has been overloaded.
15. ALARM LED: Indicates test stand’s motor has been overloaded.
16. RST/ : Changes the increment point upward.
17. TIME/ : Changes digit position when programming force limits, also changes delay between
cycles.
18. SET: Stores a program cycle to a value that the user selects using RST/ and TIME/ .
19. MODE: Selects mode of operation: Manual, Jog, Single, Continuous or Program.
20. Operation Display: Informs user of current mode of operation.
21. PULL: Test stand moves in the left movement or upward direction.
22. STOP: Stops test stand movement.
23. PUSH: Test stand moves in a tight movement or downward direction.
24. PROG START: Start the program.
25. Emergency Stop (located on the top of the test stand).