External dimensions 6 – Checkline DT-361 User Manual
Page 34
34
Memory function
•Saving the setting value when the power is OFF
• Saving 5 setting values each on internal oscillation and external synchronous emission respectively
Auto emission stop
Available to set continuous emission, or set the time to stop emission by 1 minute within the range between 1 min and 120 min.
(Set in function mode 3)
Power
AC100 to 230V(50Hz/60Hz)
Built-in NiMH battery
•Continuous emission time
Approx. 2 hours (when the emission duration is set to 3.6º)
Approx. 5 hours (when the emission duration is set to 1.0º)
•Charging time: Approx. 2.5 hours
Supplied AC adapter
•Input : AC100 to 230V
•Output : DC24V
Operating temperature
32 to 95 F (0 to 35 ºC)
Operating humidity
35 to 85%RH
Operating environment No dust and/or corrosive gases
Compliance standard
RoHS
Protection structure
Equivalent to IP65 NEMA 4X
Weight
Approx. 4 lb (1.8 kg)
Approx. 4.6 lb (2.1 kg)
Standard accessories
External I/O connector (8 pin) x 1
Dedicated AC adapter x 1
External dimensions
6
[DT-361]
[DT-365]