Specifications 5 – Checkline DT-361 User Manual
Page 33
33
Specifications
5
Model
DT-361
DT-365
Application
AC power input model
Charging battery built-in model
Internal
oscillation
emission
Emission count
60 to 120,000fpm
Setting accuracy
±0.02%
Measurement range setting
Available to set to the range between 60 fpm and 120,000 fpm, or 60 fpm
and 12,000 fpm
(Set in function mode 1)
Setting
display
resolution
(internal
oscillation)
Measurement
range:
60 to 12,000fpm
60.0 to 3,000.0
: 0.1fpm
3,000.2 to 6,000.0 : 0.2fpm
6,000.5 to 12,000.0 : 0.5fpm
Measurement
range:
60 to 120,000fpm
60.0 to 30,000
: 1fpm
30,00.2 to 60,000 : 2fpm
60,00.5 to 100,000 : 5fpm
100,010 to 120,000 : 10fpm
Function to change the emission
frequency setting
Available to change the emission frequency to an optional value
Available to change the emission frequency to double or half of the
current value
(Each press of the key changes the value to double, quadruple..., or half,
one-quarter, ...)
Phase change function
Based on the current emission phase,
For angle setting: by 1º within the range between 0º and 359º
For time setting: by 1 ms within the range between 0 and 999 ms (max.)
External
synchronous
emission
Input interface
Voltage pulse input or open collector input of Hi: 2.5 V to 12 V and Lo: 0
V to 0.5 V
(Set in function mode 4)
Pulse output interface
12 V voltage pulse output
Pulse width: Approx. 200 μs
Synchronous edge switch
Available to select either the rising edge or falling edge
(Set in function mode 2)
Frequency measurement range
40 to 35,000fpm
Available delay emission range
60 to 10,000fpm
Available phase setting range
Delay angle: by 1º within the range between 0º and 359º
Delay time: by 1 ms within the range between 0 and 999 ms (max.)
Sensor power
DC12V/max50mA
Emission
duration
Angle
Available to set by 0.1º within the range between 0.1º and 3.6º (/360º)
Time
Max. 400 μsec
Display
6-digit red LED
Setting devices
Multi-turn encoder, tact switch
Emission source
Ultra luminosity LED 18 lights
Connector
I/O signal connector
Power supply and I/O signal
integrated connector
* 1 A delay of approximately 30 μs caused by the internal calculation process will be added.