In every Pro64 network, one device will always be designated as the Control Master, the device that manages all

A‑Net resources for the network. The Control Master can be any I/O module in the network, and can be assigned

or changed by the user as needed. Only one device can be assigned as Control Master in a Pro64 network at a

time; an A‑Net Pro64 network cannot function without a Control Master.

The functions of the Control Master include:

System resource and information management

Management of

active channels (Slots)

System‑level command and control functions

Keeping track of all Pro64 devices in the network (by type and quantity)

Control of the current system‑wide

sample rate

Clock Master (analog modules only)
System lock via

password on/off for supported devices

Management of

Virtual Data Cable (VDC) resources

Management of

stereo link status

Requests to enter

Managed Mode for control with Pro64 Network Manager software

Communication with

Pro64 Network Manager software when configuring and managing a

network using a PC

The Control Master status is identified with a red LED on the front panel of the device currently assigned as the

Control Master. Depending on the type of device (rack‑mounted I/O module, AllFrame, or digital console interface

card), the method used for designating Control Master status may be different.

The Control Master LED is labeled CTL on the 6416Y2 card.

RS–232/422

STEREO LINK

6416

Y2

B

A

ON

CTL

CLK

AUTO

ERR

1 2 3 4 5 6 7 8 9 10 11 12

The Control Master LED (CTL) on the 6416Y2 card