Daisy Chain Personal Mixing System Connections

The digital output from the AN-16/i v.2 A-N

et

O

ut

jack may be connected directly to an A-16II or A-16R

Personal Mixer with a Cat-5e UTP (or better) cable to start a personal mixing system. Personal Mixers

connected in this manner need to be daisy chained, connecting the A-N

et

O

ut

of the first Personal Mixer

to A-N

et

I

N

on the next and so on. There is no practical limit to the number of Personal Mixers that can be

connected in this manner. Any combination of the A-16II and A-16R may be used.

To Additional

Personal

Mixers

A personal mixing system with six A-16II Personal Mixers connected in a daisy chain.

One A360 Personal Mixer may be used in a daisy chain personal mixing system, but because the A360 has

only one A-Net connection, it may be used in a daisy chain only if it is placed last in the chain. The use of

multiple A360 Personal Mixers requires an A-Net distributor for parallel connections.

An A360 may be used as the last device in a daisy chain.

An A360 Personal Mixer used as the last device in a daisy chain system will require the optional PS-120

Power Supply.