360 Systems MAXX-6T User Manual
Page 97
____________________________________________________________________________________
MAXX 6T Owner’s Manual
Page 97
Parity errors may occur if the Image Server loses power, or is improperly shut off. No data will be
lost, but the parity re-initialization process may take several hours. NEVER use the rear panel power
supply switch to shutdown the Image Server. Shutdown the system only by momentarily pressing
the front panel power button or selecting Start > Shutdown > Shutdown from the graphic user
interface.
Note that in some cases the power may not automatically shut off after a Shutdown is executed.
When the front panel LED indicators start flashing in response to the Shutdown command, the file
system has been successfully closed and it is safe to force the power off by holding the power
switch in for 4 seconds.
A degraded array with a drive listed as “Not In Service” or “Inaccessible” is usually indicative of a
permanent drive error, typically a single disk or cable failure, but redundant data will allow normal
operations to continue. You may first try to rebuild the array with the existing drive still installed. If
the array continues to indicate a failed drive, replace the drive and then rebuild the array. A hard
disk array must be repaired using exactly the same drive model and capacity as other drives in the
array. Because specific drive models become unavailable as time goes on, 360 Systems
recommends that maintenance spares be purchased at the same time as the Image Server.
Log-In to the RAID Utilities
Figure 39 - RAID Utilities Login Screen
To log in to the RAID utilities, perform the following steps. The above drawing will appear.
• Open the RAID utilities by selecting START>SYSTEM>RAID STATUS
• In the Login window, enter ADMINISTRATOR.
• In the Password window, make no entry; leave it blank. In the event this does not work, use
the password “3ware”.
• Click the Login button to enter the Login Utilities.