0 Auto Gain Up Control Setting [Auto Gain Up:
OFF/LOW/HIGH]
LOW:
The Auto Gain Up control with a maximum
gain increase of about 18 dB adjust the lumi
nance automatically.
HIGH;
The Auto Gain Up control with a maximum
gain increase of about 30 dB operates. If the
luminance is still insufficient, the Night Eye also
operates to adjust the luminance automatically.
OFF:
No auto gain up takes place. (Gain can be
increased manually.)
0 Manual Gain Up Control Setting [Manu Gain Up:
0 dB - 30 dB / N/Eye]
Manual setting is possible only when the Auto Gain
Up control is in the OFF position.
0 dB:
0 dB should be selected in normal cases.
1 dB - 30 dB:
Use this range if sufficient video out
put cannot be obtained even when the lens iris
is opened in shooting dark scenes.
N/Eye (Night Eye)
: Use this mode if sufficient video
output cannot be obtained even if 30 dB gain up
should be selected.
- Notes-----------------------------------------------------------------------
• In case of settings on the camera alone or when
the iris switch on the RCU (RGB) is at [AUTO], the
Auto Gain Up control may not operate if the lens
iris switch is in the manual position.
• When the AGC switch on the hybrid control panel
is set to AGC, the Auto Gain Up control operates
in the HIGH position.
AGC Switch
I
«now AWC
PER
a
I
é
HHiH * iC *TW
MODE SHUTTER I I
SCÉNE
J
FJLE
à in
' (9
Hybrid Control Panel
Notes----------------------------------------------------------------------
• Only 0 dB, 9 dB, or 18 dB can be selected in
case of using the RCU (RGB).
• 0 dB when the manual GAIN switch on the hybrid
control panel is at LOW, 9 cB when it is at MID, or
18 dB when it is at HIGH.