External timing input connector (ext timing in), Password setting switch (password set), Power cord – Panasonic WJ-SQ508 User Manual
Page 7: Grounding screw, External tally connector (tally out), Note, Master/slave connectors (m/s in/out), Alarm output terminal (alarm out), Alarm signal input s terminals (alarm in), Recover input terminal (recover in)
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
![background image](/manuals/652463/7/background.png)
32. External Timing Input Connector (EXT TIMING IN)
The sequential switching interval of WJ-SQ508 can be
externally controlled by a Time Lapse VTR.
Supply the timing pulse from the Time Lapse VTR to
this connector.
33. Password Setting Switch (PASSWORD SET)
The WJ-SQ508 contains a password function to
protect a program from being changed by unauthorized
persons. A password of five digits can be set by this
switch.
Refer to the setting up of the password on page
8
.
34. Power cord
35. Grounding Screw
36. External Tally Connector (TALLY OUT)
When using an external display in addition to the LEDs
of the Sequence Switch (3), the Spot Switches (4) and
the Program Switch (20), utilize this connector for the
external tally out signals.
The pin configuration is shown below.
An open collector output is provided to each pin. The
supply voltage is 16V DC maximum and the current is
100 mA
(D---------
-------
1
. PROG
-------
9
. GROUND
2 SEQ
- 10. SPOT 2
(
45
)--- -
3 SPOT
8
to; ■
(
0
>-------- -------l"l. SPOT1
4
.qpoTT
_
if?)____ _ - -
12
R «iPOT R
gj)----------- * -
- - -
(S^..........
U»
0
\ 1 J
-------14,
7
QPnr
A
ij)
1
-
------- a SPOT 3
Note:
This connector can be used as a external remote
control connector. Ask qualified service personnel
for the modification of the circuit.
37. Spot Channel Output Connectors
(SPOT CH OUT 1-4 CH/5-8 CH)
The command signal of the "TALK" function is supplied
to the Spot Channel Input Connector (4) of the
WJ-DA464 from this connector.
Note:
1. The signal from 1-4 CH should be supplied to 1-4
CH of the Spot Channel Input Connector (4) of the
first WJ-DA464.
The signal from 5-8 CH should be supplied to 5-8
CH of the Spot Channel Input Connector (4) of the
second WJ-DA464.
Refer
to
the
operating
instructions
of
the
WV-CU300 for "TALK" function,
1
. TALK ALL
2. CH SEL
1
3. CH SEL 2
4. CH SEL 3
5. TALK SW
1
6
. GROUND
38. Master/Slave Connectors (M/S IN/OUT)
When multiple WJ-SQ508 are used in a master- slave
operation, connect the 5 pin interface cable (provided)
between these
connectors of the WJ-SQ508. A
master- slave control data signal transmits among the
WJ-SQ508.
1. SCKO
2. SBO
3. CNT I/O
4. TIM I/O
5. GND
39. Alarm Output Terminal (ALARM OUT)
When the Alarm Signal Input Connector (40) or the
Quick Scan Input Terminal (43) is activated, the alarm
output signal will be supplied from this connector. This
output consists of a open collector circuit. The supply
voltage is 16V DC maximum and the current is 100 mA
40. Alarm Signal Input s Terminals (ALARM IN)
A alarm sensor unit which has an open collector circuit
can be used with this input connector.
When this terminal is activated (grounded), the alarm
buzzer sounds and the Alarm Indicator (7) blinks. At
the same time, the signal at the Alarm/Sequence Video
Output Connector (22) outputs the video signal from
the alarmed camera site.
41. Recover Input Terminal (RECOVER IN)
The WJ-SQ508 returns to the normal operation mode
from the alarm mode when the recover signal from a
Time Lapse VTR is supplied to this connector.
Note;
When the alarm mode is canceled by the
WV-CU300,
the
Alarm
Indicator
(7)
of
the
WJ-SQ508 changes from a blinking state to the
continuously on state.
42. Reset Output Terminal (RESET OU'H
When a Time Lapse VTR receives the reset signal
supplied from this connector, the Time Lapse VTR
returns to the normal operation mode from the alarm
mode.
-
6
-