(1 ) Setting up of WJ-MP404
Same as Example-
1
, item
-(1
).
(2) Setting up of No.1 WJ-SQ508
Same as Example-
1
, item-(2).
----- 3,000 fl--------------------
No.1
No.2
------------- *
rWJ-SQ508
WJ-SQ508
WV-CU300
.
-------C
f t —
------------------- ►
1 }
WJ-MP404
: Aft
2
)
3)
4)
No
.1
WJ-SQ508: B ft
No,2 WJ-SQ508 : C ft
A+C+D < 3.000ft
(3) Setting up of No
.2
WJ-SQ508
Replace "A + B' of the table in Example-
1
, item-(2) with
the ”A + C + D” of the diagram above.
Note:
The distance D should not be long due to no cable-loss compensation switch on WV-CU300.
CABLE CONNECTION
A. DATA BUS CONNECTION
1. Cable Connections
1-1
The two BNC connectors for DATA IN/OUT on
the WJ-MP404, WJ-SQ508 and the WV-CU300 are
internally connected and are identical.
1-2 The Data Bus Connection is looped through all units
with the first and last units being automatically
terminated with 75i) and all other units being Hi-Z
loop through.
2.
Data Clock Switch Selection
2-1 Set the Data Clock Switch on the first unit connected
to the Data Bus to the "SND" so that this unit is the
Data Clock supplier. Set the Data Clock Switch on all
other unit to the "RCV* position.
2-2 Data are transmitted and received to and from each
unit connected to the Data Bus, in addition to the Data
Clock, through the single coaxial cables.
WJ-MP404
WJ-MP404
WV-CU300
-
1 5
-