1
) ALARM/SEQ TITLE
♦ ALM/SEQ TITLE OFF
ON
When
this
item
is
ON,
the
camera
title
will be superimposed on the picture at the
Alarm/Sequence Video Output Connector {22).
When this is in the OFF mode, no camera title
will be superimposed on the picture.
Press either the Backwards Character Selection
Switch (15) or the Forward Character Selection
Switch (16) to select the *ON "or 'OFF’character.
After the selection has been done, press the Shift
Switch (
12
) to move on to the next item.
(2) AUTO SKIP
. AUTO SKIP ON
T
OFF
When this item is "ON*, sequential switching is
performed only where a camera input exists.
An input where no camera is connected will be
skipped during the sequence. When this item is
"OFF", the auto skip function will not be performed.
All camera inputs are involved in the sequential
switching even if no camera exists at the camera
input.
Press either the Backward Character Selection
Switch (15) or the. Forward Character Selection
Switch (16) to select "ON "or”OFF"character;
After the selection has been done, press the Shift
Switch (12) to move on to the next item.
(3) ALM-TIME
» ALM-TIME
5 (MIN)
T
OFF to 5
The alarm time can be selected from OFF to 5
minutes in
1
minute increments.
Press either the Backward Character Selection
Switch (15) or the Forward Character Selection
Switch (16) to select the time.
When "OFF" is selected, a recover signal to the
Recover Input Connector (41) is required to return
to the normal operation mode.
After the selection has been done, press the Shift
Switch (
11
) to move to the next item.
(4) QS-TIME
♦ QS-TIME 400.8 (mS)
66.8 to EXT
•
The quick scanning time in the alarm mode can be
selected from
66
.
8
ms, 133.6ms, 200.4ms, 267.2ms,
334.0ms, 400.0ms, or EXT.
•
Press either the Backward Character Selection
Switch (15) or the Forward Character Selection
Switch (16) to select the time.
•
When "EXT" is selected, an external timing pulse
from a Time Lapse VTR to the External Timing
Connector (32) is required.
•
After the selection has been done, press the Enter
Switch (11) to memorize the new menu and to
enter the menu for setting up the sequential mode.
4.
Setting up the sequential mode
•
The following menu is displayed on the monitor.
This menu is for programmed sequential switching
when operating the Program Switch (20).
•
When this menu is selected, the channel (CH)
for order number
1
blinks. Select which channel
(camera) will occupy order number
1
by using the
Backward Character Selection Switch (15) and
the Forward Character Selection Switch (16).
•
Press this Right Shift Switch (13). The DWELL
blinks. Set the dwell time of the sequential
switching
by
using
the
Backward
Character
Selection Switch (15) and the Forward Character
Selection Switch (16). The dwell time can be set
from 0.5 sec. to 30,0 sec. in 0.5 sec increments.
ORDER CH DWELL BYPASS
(S)
1
1
2
PASS
2
3
2
♦
3
5
2.5
♦
4
7
3
♦
5
2
2
*
6
4
1.5
*
7
6
3.5
*
8
8
3
*
Press the Right Shift Switch (13). The BYPASS
blinks.
Select
"PASS"
or
by
using
the
Backward
Character, Selection Switch (15) or the Forward
Character Selection Switch (16).
When "PASS" is selected, the camera of this
channel will be skipped. When the is selected,
the camera of this channel will be included in the
a sequential operation.
Repeat above procedure fpr all cameras.
After the setting up has been done, press the Enter
Switch (
11
) to memorize the new menu and then
press the Program/End Switch (17) to conclude
the programming of the menu.
- 1 0 -