SYSTEM ERROR TABLE
• When a system component has its controls set up
incorrectly, an error indication will appear automatically
on the video monitor of the WV-CU300.
In this case, refer to the table below and reset the
controls to their correct positions.
, Cause
Location where error exists and its error indication
Remedy
WV-CU300
WJ-SQ508
WJ-MP404
A1
•
Data Clock
Switch of all
WJ-MP404 & WV-CU300 are
set to RCV position
• Broken data bus line even in
RCV position
CU ERROR: A
1
Designate 1 unit as data clock
supplier & set switch to "SND".
A2
Data Clock Switches of two or
more WJ-MP404& WV-CU300
are set to SND position
CU ERROR; A2
MP ERROR: A
2
Set only
1
unit's Data Clock Switch
to "SND" position.
B1
SEQ Unit No. is set to 1-0; 1-9;
2-0; 2-9; 3-0 or 3-9.
CU ERROR: Bl
The buzzer
sounds
Correct
Unit
Number
Switch
setting
on
WJ-SQ508
or
WV-CU300.
B2
Controller No. is set to 0,
6
, 7,
8
or 9.
CU ERROR: B2
Correct Controller Unit Number
Switch setting.
Cl
Unit No. of components are
duplicated
within
the
same
station.
CU ERROR: Cl
See the manual
of WJ-SQ508.
MP ERROR: Cl
Correct
Unit
Number
Switch
setting on duplicated component.
D1
Broken data bus line or non
termination.
CU ERROR: D1
MP ERROR: D1
Check
data
bus
cabling
for
defective connector, cable, etc.
Note on error A2:
The last component which has set its Data Clock Switch to the SND position becomes the error location.
Note 1:
With a broken data bus line or non-termination, 2 kinds of error indications are available on each monitor as shown below. The
difference between these systems is the location of the "SND" unit.
(
1
)
©X
J
X (1)
■—X—
I—X—
(3)
MP^04
(SND)
(RCV)
SO50B
©
(
2
)
©
J
X (2)
(3')
■—X-
I—X-
(3)
(SND)
X®
r*-
X
L_
MP404
(RCV)
SQ50B
SO 508
Trouble
point
Error indication
onM
1
monitor
Error indication
on M2 monitor
0
)
CU ERROR: A
1
CU ERROR: A
1
(
2
)
CU ERROR: A
1
CU ERROR: A1
(3)
MP ERROR: D1
CU ERROR: A1
(4)
MP ERROR: D1
MP ERROR: D
1
(5)
MP ERROR: D1
MP ERROR: D1
Trouble
point
Error indication
on Ml monitor
Error indication
on M2 monitor
(f)
—
CU ERROR: D
1
(
2
)
—
CU ERROR: D
1
(3)
CU ERROR: A1
CU ERROR: D
1
(4)
—
CU ERROR: D1
(5)
—
CU ERROR: D1
- 1 3 -