6. Masler/Slave operation with VTR
SPOT/SeQ
OUT
ALARM/SEQ OUT
(/¡^/Unil No,1
(g) Single alarm mode:
(
1
) SPOT/SEQ OUT
i,
starts sequencing out once every second
when the unit was in SEO mode.
ii.
stays spot mode when the unit was in SPOT
mode.
(3) ALARM/SEQ OUT —* Obtains the alarmed picture.
(h) Multiple alarm mode:
(1) SPOT/SEQ OUT
i.
starts sequencing out once every second
when the unit was in SEQ mode.
ii.
stays spot mode when the unit was in SPOT
mode.
(2) ALARM/SEQ OUT —> Alarmed channels start
sequencing out once every one second.
(i} Quick Scan alarm mode:
(
1
) SPOT/SEQ OUT
i.
starts sequencing out once every second
when the unit was in SEQ mode.
ii.
stays spot mode when the unit was in SPOT
mode.
(
2
) ALARM/SEQ OUT —> starts sequencing for all
pictures in QS- TIME.
(a) Sequence time: Set by timing pulse from VTR for all
WJ-SQ508. The Dwell Time Control (5) of (A) Sequential
Switcher should be in the EXT position,
(b) Controls:
(1)
Master/Slave Switch (27) to Master position for
(A) WJ-SQ508, to Slave position for (B), (C)
WJ-SQ508
(2) Station Number Switch (29) should be same.
(3) Unit Number Switch (30) set to 1 for (A) WJ-SQ508,
2 for (B) WJ-SQ508 and 3 for (C) WJ-SQ508.
(4)
Dwell Time Control (5) to proper level for (A)
WJ-SQ508. Not specified for (B) (C) WJ-SQ508.
(c) System stops when the power of VTR or (A) WJ-SQ508
is turned off.
(d) Normal sequence mode:
(1)
SPOT/SEQ OUT —» All cameras are switched by
timing pulse from the VTR
(2) ALARM/SEQ OUT —► All cameras are switched by
timing pulse from the VTR.
(e) Program sequence mode;
(1)
SPOT/SEQ OUT —> Program sequence is
performed for each WJ- SQ508 triggered by timing
pulse from VTR
(2)
ALARM/SEQ OUT —> Program sequence is
performed for each WJ- SQ508 triggered by timing
pulse from VTR
(f)
Spot mode:
(
1
) SPOT/SEQ OUT —^ Spot picture is obtained.
(2)
ALARM/SEQ OUT —v Continues the sequence
mode.