6. Masler/Slave operation with VTR

SPOT/SeQ

OUT

ALARM/SEQ OUT

(/¡^/Unil No,1

(g) Single alarm mode:

(

1

) SPOT/SEQ OUT

i,

starts sequencing out once every second

when the unit was in SEO mode.

ii.

stays spot mode when the unit was in SPOT

mode.

(3) ALARM/SEQ OUT —* Obtains the alarmed picture.

(h) Multiple alarm mode:

(1) SPOT/SEQ OUT

i.

starts sequencing out once every second
when the unit was in SEQ mode.

ii.

stays spot mode when the unit was in SPOT

mode.

(2) ALARM/SEQ OUT —> Alarmed channels start

sequencing out once every one second.

(i} Quick Scan alarm mode:

(

1

) SPOT/SEQ OUT

i.

starts sequencing out once every second
when the unit was in SEQ mode.

ii.

stays spot mode when the unit was in SPOT

mode.

(

2

) ALARM/SEQ OUT —> starts sequencing for all

pictures in QS- TIME.

(a) Sequence time: Set by timing pulse from VTR for all

WJ-SQ508. The Dwell Time Control (5) of (A) Sequential

Switcher should be in the EXT position,

(b) Controls:

(1)

Master/Slave Switch (27) to Master position for

(A) WJ-SQ508, to Slave position for (B), (C)

WJ-SQ508

(2) Station Number Switch (29) should be same.
(3) Unit Number Switch (30) set to 1 for (A) WJ-SQ508,

2 for (B) WJ-SQ508 and 3 for (C) WJ-SQ508.

(4)

Dwell Time Control (5) to proper level for (A)

WJ-SQ508. Not specified for (B) (C) WJ-SQ508.

(c) System stops when the power of VTR or (A) WJ-SQ508

is turned off.

(d) Normal sequence mode:

(1)

SPOT/SEQ OUT —» All cameras are switched by

timing pulse from the VTR

(2) ALARM/SEQ OUT —► All cameras are switched by

timing pulse from the VTR.

(e) Program sequence mode;

(1)

SPOT/SEQ OUT —> Program sequence is

performed for each WJ- SQ508 triggered by timing

pulse from VTR

(2)

ALARM/SEQ OUT —> Program sequence is

performed for each WJ- SQ508 triggered by timing

pulse from VTR

(f)

Spot mode:
(

1

) SPOT/SEQ OUT —^ Spot picture is obtained.

(2)

ALARM/SEQ OUT —v Continues the sequence

mode.

- 2 1 -