6006600b5o, Doooooobs, O.ood6oo6$oir – Panasonic WJ-SQ508 User Manual
Page 19
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
4. Parallel connection with VTR
SPOT/SEQ OUT
□ □
ALARM/SEQ OUT
(A)
VTR
o.ood6oo6$oir №
ooodooDbiSo
, ®
0.000000000
6006600
b5o
iVrrrri I C
SPOT/SEQ OUT
(C)
ALARM/SEQ OUT
6
oodbood™-
DOOOOOObS^
¥ _
(2) ALARM/SEQ OUT —> WJ-SQ508 in spot mode
and the other WJ-SQ508 are switched by to the
timing pulse from the VTR.
(g) Single alarm mode;
(
1
) SPOT/SEQ OUT - When the unit (B) is alarmed,
i.
the unit (B) and (C) starts sequence in every
one second.
ii.
the unit (A) continues a previous operation.
(2)
ALARM/SEQ OUT —» WJ-SQ508 in alarm mode
fixed to the alarmed picture. Other WJ-SQ508
continue the sequence mode synchronized with
timing pulse from the VTR.
(h) Multiple alarm mode:
(
1
) SPOT/SEQ OUT - When the unit (B) is alarmed,
i,
the unit (B) and (C) starts sequence in every
one second.
ii,
the unit (A) continues a previous operation.
(
2
)
ALARM/SEQ
out
—^ Alarmed channels of
alarmed WJ-SQ508 start sequencing out once
every
second.
Other
WJ-SQ508
continuethe
sequence mode synchronized with timing pulse
from the VTR.
(i)
Quick Scan alarm mode;
(
1
) SPOT/SEQ OUT - When the unit (B) is alarmed,
i,
the unit (B) and (C) starts sequence in every
one second.
ii.
the unit (A) continues a previous operation.
(2) ALARM/SEQ OUT starts sequencing out all
pictures in the alarmed WJ-SQ508 in QS-TIME.
Other WJ-SQ508 continued the sequence mode
synchronized with timing pulse from the VTR.
Note:
The Time Lapse VTR can be used with each
Sequential Switcher.
(a) Sequence time; Set by timing pulse from VTR for all
WJ-SQ508.
(b) Controls:
(1)
Master/Slave Switch (27) set to Master position
for all WJ-SQ508.
(
2
)
Station Number Switch (29) & Unit Number Switch
(30) are not specified.
(3) Dwell Time Control (5) of all WJ-SQ508 set to EXT
position.
(c) The Sequence mode of the system stops when the
power of the VTR is turned off due to no timing pulse.
(d) Normal sequence mode:
(1)
SPOT/SEQ OUT All WJ-SQ508 are switched
by the timing pulse from VTR
(2)
ALARM/SEQ OUT All WJ-SQ508 are switched
by the timing pulse from VTR.
(e) Program sequence mode:
(
1
) SPOT/SEQ OUT All WJ-SQ508 are switched
by the timing pulse from VTR with self programmed
menu.
(f)
Spot mode:
(
1
) SPOT/SEQ OUT -> WJ-SQ508 in spot mode
shows the spot picture. Other WJ-SQ508 are
synchronized to the timing pulse from the VTR.
- 1 9 -