Master/Slave Configuration
In addition to the Standard Configuration described in
item-
1
, this system offers a master/slave operation of the
Sequential Switchers WJ-SQ508.
• Up to sixty-four cameras are available in this system.
The camera functions of four cameras and optional
accessories are controlled by the WV-CU300 through
the WJ-MP404 in this example.
C. Advanced Application-1
• The master WJ-SQ508 sends/receives the control
data to/from the slave WJ-SQ508.
WV-BL600
WV-7140/WV-7141
WV-6L200 or equivalent
Up to 64
Cameras
WJ-SQ508
N0.0
WJ-0A464
Set the switches of each unit as follows.
WV-CU300:
SEQ NO;
STATION .................................. 1
UNIT ......................................... 1
CONTROLLER UNIT NO . . . . 1
DATA CLOCK ..................... RCV
WJ-MP404:
DATA CLOCK .................... SND
CH SELECT ..................... 1-4CH
UNIT NO . . . : ............................ 1
WJ-SQ508:
MASTER/SLAVE . . . . MASTER
(No.
1
)
STATION NO .......................... 1
UNIT NO ................................... 1
WJ-SQ508:
MASTER/SLAVE ........... SLAVE
(N
0
.
8
}
STATION NO .......................... 1
UNIT NO ....................................
8
- 2 3
-