4 configuration mode, 1 accessing the configuration mode, Chapter 4 configuration mode – Dillon Quick-Check Wire Tension Meter (Red) User Manual

Page 26: Accessing the configuration mode

background image

26

Quick-Check Red User Instructions

4 Configuration Mode

4.1 Accessing the Configuration Mode

You need to access the Configuration mode to perform certain tasks. Access to some
of these tasks may be restricted by a supervisor password.

To access Configuration mode:

1.

From normal operating mode, press the Right Arrow softkey…

A new softkey set, shown below, appears:

2.

Press the Config softkey…

The following is displayed:

3.

Use the Num and Adv keys to enter the Config password. Default is 0. After
the number is displayed, press the Enter key…

The following is displayed:

Units

Log

Setup Config

lbf

7/16 6X19

Shv:S

The Num keys increment and decrement the displayed numbers. The Adv key
moves the cursor to the next digit position.

Default Configuration password is 0. If a new password is lost or forgotten, contact
your Dillon distributor.