beautypg.com

Dillon GTX Plus Force Gauge User Manual

Page 8

background image

GTX-Plus Series User’s Manual REV 2.1

8

Peak Tension

symbol


Figure 3b Peak Tension

Peak-Compression mode Press MODES key until

appeared on the display. The display will show the maximum

compressive force. See Figure 3c

Peak Compression

symbol



Figure 3c Peak Compression

Dual-Peak mode Press MODES key until

appeared on

the display. The display will show the highest tensile force and the

highest compressive force. The current load being applied to the load

sensor is also displayed. See Figure 3d

Peak tension

reading


Dual symbol

Peak compression

reading

Load currently

applied to load

sensor

Figure 3d Dual Peak

Resetting the gauge Press RESET key to clear both maximum
registers and prepare for detecting the next maximum readings.

Backlit Display When you press any key or applied forces to load
sensor greater then 0.5 % of full scale the backlight will go on for 6

seconds.