Using the GTX

Fitting Accessories


Couple fittings directly to the load cell stem or use an extension

rod. The threads are 10-32 in capacities up to 1000 N, and 5/16-18 in

the 2500 N capacity.

Ensure that fixturing does not contact the force gauge case.

Ensure that anything coupled to the gauge is screwed finger-tight

only. Excessive torque can damage the load cell and is not covered by

warranty.

Mounting to Test Stand

The two 10-32 threaded holes on the rear of the gauge can be

used for mounting the gauge. The distance between the holes is 2.25

inch. A versatile stand mounting plate is available to couple the force
gauge to many brands of test stands.

Powering up

As show in Figure 1 the control panel has eight keys.

Figure 1 GTX control panel

To power up the gauge press the ON/OFF key. A short self-test

runs during which the display will show the capacity in Newtons.