Maintenance

9161 Ethernet Network Interface Device User’s Manual

Check Optical Power Levels

39/(42 Blank)

Figure 5-2. Measuring Receiver Input Power

5.2.3 Calculating Fiber Link Attenuation

Link attenuation measurement identifies potential problems with links that are on the threshold of
receiver sensitivity. Measure optical fiber links at the shortest wavelength of operation, as it is the
limiting factor in the loss budget. Use a power meter calibrated for the laser source, then factor in
approximately 1 dB for the connector loss from the patch cables between the 9161 and the local
device. (Each fiber connection can generate 0.5 dB of additional loss.)

NOTE: If you cannot determine the Rx sensitivity, contact Canoga Perkins

Technical Support for assistance.

Follow these steps to calculate fiber link attenuation:

1. Determine transmitter output power as described in paragraph 6.2.1 above.

2. Determine receiver input power as described in paragraph 6.2.2 above.

3. Subtract receiver input power from transmitter output power. The result is the fiber link

attenuation.

Transmit Output Power

-7.0 dBm

Receiver Input Power

-28.2 dBm

Fiber Link Attenuation

21.2 dB

FIBER OPTIC
TRANSMITTER

FIBER OPTIC
RECEIVER

OPTICAL

POWER

METER

-24dBm

λ

= 1300 nm

FIBER OPTIC
TRANSMITTER

FIBER OPTIC
RECEIVER

OPTICAL

POWER

METER

-24dBm

λ

= 1300 nm

LOCAL SITE

REMOTE SITE