3 alarm output configuration, Alarm output configuration -6 – CANOGA PERKINS 6703 CWDM Transponder User Manual
Page 18

EdgeAccess Universal Chassis System
TRAP CONFIGURATION
1) Master Trap Control Enabled
2) Diagnostics Trap Enabled
3) Cold Start Traps Enabled
4) Power/Fan Malfunction Traps Enabled
5) Alarm Input Traps Enabled
Local Port Remote Port
6) Receive Level Traps Enabled Enabled
7) SpeedCop Violation Traps Enabled Enabled
8) CDR Unlock Traps Enabled Enabled
9) SFP Transceiver Traps N/A Enabled
Figure 8. Trap Configuration Menu
3.4.3 Alarm Output Configuration
The alarms for the 6703 are output-only through a data bus to the rear panel on a UCS 1001 or 1040
standalone enclosure, or to the CIM in the same chassis, which routes any alarm to an external alarm.
For details, see the Model 1200 Chassis Interconnect Module User Manual, UCS 1001 Chassis User
Manual, or the Model 1040 Standalone Enclosure User Manual.
You can set each alarm condition to Major, Minor, or Off. To set the alarms, see Figure 9 and
Table 3, and follow these steps:
1. From the System Configuration menu type
3
, "Alarm Output Configuration," and press
The Alarm Output Configuration screen appears.
2. Type the number for the alarm you want to set and press
3. Press
ALARM OUTPUT CONFIGURATION
1) Factory Default
2) Power Supply/Fan Alarm Off
3) Power On Self Test Alarm Off
Remote
Local Port Active Inactive
4) Receive Level Alarm Minor Major N/A
5) SpeedCop Violation Alarm Off Off
6) CDR Unlock Alarm Off Off
7) SFP Transceiver Alarm N/A Minor
Figure 9. Alarm Output Configuration Menu
CWDM Transponder Model 6703