2 dual installation user data copy error messages – BendixKing KLN 900 - Pilots Guide User Manual
Page 188

8-3
8.1.2 Dual Installation User Data Copy Error
Messages
The message shown in figure 8-10 will be displayed on
the receiving unit if it is unable to make a connection to a
transmitting unit within 1 minute. (NOTE: The transmit-
ting unit will not time out.) The most likely cause of this
problem is that the RS-232 interface between the two
units has not been installed properly. Contact the
installer of your KLN 900 units to resolve the problem.
If an unrecoverable communication error occurs during
the transfer, the message shown in figure 8-11 may be
displayed on either unit. This message may appear if the
procedure in section 8.1.1 was not followed properly or if
there is a problem with the database card on the receiv-
ing unit.
If the message shown in figure 8-12 appears, simply
remove the data card and carefully move the tiny write-
protect switch on the PCMCIA card to the write-enabled
position. Then, insert the card back into the KLN 900,
cycle the power Off then On, and repeat procedure 8.1.1.
Rev 2
Figure 8-10
UNABLE TO ESTABLISH
CONNECTION WITH
TRANSMITTING UNIT
ACKNOWLEGE?
CRSR
ent
CRSR
Figure 8-11
USER DATA TRANSFER
FAILED
OPERATION CANCELED
ACKNOWLEGE?
CRSR
ent
CRSR
Figure 8-12
DATA BASE CARD
IS WRITE PROTECTED.
COPY OPERATION
IS CANCELED.
ACKNOWLEGE?
CRSR
ent
CRSR